Summary for Test 2025-08-30-1-1
Test performed: ASTM C136-19Project Information
| Project Identifiers | Project ID: 1000264 DEA: 060W90U4 EFIS: 0623000128 |
|---|---|
| DIST-CO-RTE-PM | 06-TUL-198,216-R11.6/R11.9,R0.0/2.7 |
| Award Date | 08/29/2024 |
| Closeout Date | Not set |
| Work Description | HMA AND MODIFYING SIGNAL AND LIGHTING SYSTEMS. |
| Location Description | TULARE COUNTY IN AND NEAR VISALIA ON ROUTE 216 FROM 0.2 MILE SOUTH OF LOVERS LANE UNDERCROSSING TO 0.2 MILE EAST OF MCAULIFF STREET AND ON ROUTE 198 FROM 0.1 MILE WEST TO 0.2 MILE EAST OF LOVERS LANE UNDERCROSSING |
| QA Service Level | 1 (Verified on 04/15/2024) |
Sample Information
| Sample Taken Date | 08/30/2025 | Sample Unique Key | 1 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 08/30/2025 |
| Sample type | Quality Control | A brief description of the sample | Washed Concrete Sand |
| The quantity of what the sample constitutes | Week's worth of deliveries | From where was the sample collected | Supplier |
| First name of sampler or witnessed by | Daniel | Last name of sampler or witnessed by | Mills |
| Title of sampler | Asphalt Technician | Telephone number of sampler | |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Vulcan Materials | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | Pleasanton-SMARA-91-01-0010 |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
| The plant number | A detailed description of where the material sample was collected | Stockpile @ Supplier | |
| Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | fine | |
| The concrete mix design number | Lot number | ||
| Sublot number | Aggregate Mix Number |
Test Details
DIME Sample ID: 2025-08-30-1
DIME Test ID: 2025-08-30-1-1
Testing Lab: Oldcastle Precast, Incorporated - Pleasanton
Test Method: ASTM C136-19: Standard Test Method for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2025-09-03
Test Results
What type of gradation is being tested?: Fine Aggregate
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Has the fine aggregate sample been reduced? (question for combined gradation type): No
Input Type: Calculated
Tester's full name: Daniel Mills
Date of test: 08/30/2025
Cumulative percent passing the 3/8 in. sieve: 100 %
Cumulative percent passing the #4 sieve: 100 %
Cumulative percent passing the #8 sieve: 89 %
Cumulative percent passing the #16 sieve: 59 %
Cumulative percent passing the #30 sieve: 34 %
Cumulative percent passing the #50 sieve: 17 %
Cumulative percent passing the #100 sieve: 7 %
Cumulative percent passing the #200 sieve: 2.9 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 9/3/2025 ✔