Summary for Test 2025-08-25-77-1

Test performed: ASTM C39-18

Project Information

Project IdentifiersProject ID: 995202
DEA: 033H6104
EFIS: 0318000019
DIST-CO-RTE-PM03-PLA-80-42.7/49.3
Award Date02/15/2024
Closeout DateNot set
Work DescriptionRDWY EXC, HMA, JPCP, ALT PIPELINER, STEEL SOLDIER PILE, MOD LTG SYSTEM
Location DescriptionPLACER COUNTY ABOUT 9.4 MILES NORTH OF COLFAX FROM 0.5 MILE WEST OF MONTE VISTA OVERCROSSING TO 0.3 MILE EAST OF DRUM FOREBAY OVERCROSSING
QA Service Level1 (Verified on 11/13/2023)

Sample Information

Sample Taken Date08/25/2025 Sample Unique Key77
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/25/2025
Sample typeQuality Control A brief description of the samplecompressive cylinders
The quantity of what the sample constitutesdays production From where was the sample collectedManufacturer
First name of sampler or witnessed byWilfredo Last name of sampler or witnessed byBucaneg
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameRinker Florin Rd Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design number5b
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected2-15584
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedbase of besser machine Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2025-08-25-77
DIME Test ID: 2025-08-25-77-1
Testing Lab: Rinker Materials
Test Method: ASTM C39-18: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2025-09-02

Test Results


Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Calculated
Tester's full name: Wilfredo Bucaneg
Date of test: 09/02/2025
Average diameter of cylinder 1: 4.00 in
Average diameter of cylinder 2: 4.00 in
Capped in accordance with?: ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 3: 4.00 in
Maximum load on cylinder 1: 67015 lb
Maximum load on cylinder 2: 69010 lb
Maximum load on cylinder 3: 70905 lb
Type of fracture pattern of cylinder 1: 4
Type of fracture pattern of cylinder 2: 2
Type of fracture pattern of cylinder 3: 4
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Correction factor for cylinder 3: 1.00
Age of specimen: 8 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 0 in^2
Cross sectional area of cylinder 2: 0 in^2
Cross sectional area of cylinder 3: 0 in^2
Compressive strength (to nearest 10 psi): 0 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 9/2/2025