Summary for Test 2025-08-21-7-11

Test performed: ASTM E18-20

Project Information

Project IdentifiersProject ID: 1001249
DEA: 031N5504
EFIS: 0325000797
DIST-CO-RTE-PM03-BUT-70-35/36
Award Date11/20/2024
Closeout DateNot set
Work DescriptionMajor Damage Restoration
Location DescriptionBUT 70 Viaduct
QA Service Level1 (Verified on 05/06/2025)

Sample Information

Sample Taken Date08/21/2025 Sample Unique Key7
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing08/21/2025
Sample typeAcceptance A brief description of the sampleAllthread anchor rod assembly
The quantity of what the sample constitutes175 From where was the sample collectedDistributor
First name of sampler or witnessed byStephen Last name of sampler or witnessed byHaynes
Title of samplerQuality Assurance Inspector Telephone number of sampler5105931179
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility namePacific Bolt Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormB408-027-25 Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)
Heat Number(s)Bar 20948870 Nut 234979 Washer 208374 Nut Mfg. Lot Number(s)40610-234979
Washer Mfg. Lot Number(s)0320-418 Bolt SpecificationASTM F1554 GR105
Bolt Length(s)28.75" Nut SpecificationASTM A194
Washer SpecificationASTM F436 FinishASTM F2329
Diameter/Size1-1/4" Bolt Mfg. Lot Number1.1875
Rocap Test Requirement(s) Lubricant Requirements(s)
Washer Inner Diameter(s)

Test Details

DIME Sample ID: 2025-08-21-7
DIME Test ID: 2025-08-21-7-11
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Test Release Date: 2025-09-08

Test Results


Input Type: Calculated
Tester's full name: Andrew Auvinen
Date of test: 09/02/2025
Sample No.: 1A
Rocap Number: no data
Heat Number(s): no data
Mfg. Lot Number: 40610-234979
Finish Coating: ASTM F2329 - Hot Dip
Product Markings: no data
Size: 1.25 in
Bolt Length: no data
Hardness Reading Scale: C Scale
Spacing: Ok
Hardness Reading Average: 31.5
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 9/8/2025