Summary for Test 2025-07-31-27-7

Test performed: AASHTO T240-23

Project Information

Project IdentifiersProject ID: 1000510
DEA: 060W79U4
EFIS: 0622000189
DIST-CO-RTE-PM06-KER,TUL-99-56.4/57.6,0.0/13.5
Award Date04/10/2025
Closeout DateNot set
Work DescriptionRDWY EXC, HMA, AGGREGATE BASE, CRCP, SIGN STR, AND STR EXC.
Location DescriptionKERN AND TULARE COUNTIES IN AND NEAR DELANO FROM 0.2 MILE SOUTH OF CECIL AVENUE OVERCROSSING TO 0.7 MILE NORTH OF AVENUE 100 OVERCROSSING
QA Service Level1 (Verified on 08/26/2024)

Sample Information

Sample Taken Date07/31/2025 Sample Unique Key27
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing08/04/2025
Sample typeQuality Assurance A brief description of the sample64-16
The quantity of what the sample constitutes1 can of 64-16 From where was the sample collectedSource
First name of sampler or witnessed byJake Last name of sampler or witnessed byG
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameSan Joaquin Refining Co Inc Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormC753412 Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeAsphalt Binder Performance GradePG 64-16
Modified Lot number
Sublot number Tank number
Time of sample HMA Supplier
Certified Asphalt SupplierSan Joaquin Refinery - Bakersfield CA MultigradeNo
Multigrade Type Asphalt Binder Mix Number

Test Details

DIME Sample ID: 2025-07-31-27
DIME Test ID: 2025-07-31-27-7
Testing Lab: WSP USA - Phoenix
Test Method: AASHTO T240-23: Standard Method of Test for Effect of Heat and Air on a Moving Film of Asphalt Binder (Rolling Thin-Film Oven Test)
Test Release Date: 2025-08-29

Test Results


Is mass change based on one or two containers?: Two
Is mass change correction factor needed?: Yes
Input Type: Measured
Tester's full name: WSP
Date of test: 08/27/2025
Any material loss from containers during heating process/testing?: No
Mass of container #1 before test (m1i): 205.011 grams
Mass of container #2 before test (m2i): 196.155 grams
Mass of container #1 after test (m1f): 204.964 grams
Mass of container #2 after test (m2f): 196.108 grams
Mass of empty container #1: 169.909 grams
Mass of empty container #2: 161.443 grams
Mass correction factor: 0.006
Average mass change: -0.129 percent
General comments (publicly viewable) (Max 1000 characters): Mass change

Test was verified on 8/29/2025