Summary for Test 2025-08-14-87-9
Test performed: AASHTO T308-10Project Information
| Project Identifiers | Project ID: 1000211 DEA: 112N0204 EFIS: 1117000168 |
|---|---|
| DIST-CO-RTE-PM | 11-SD-76-R17.2/24.1 |
| Award Date | 06/14/2024 |
| Closeout Date | Not set |
| Work Description | COLD PLANE AND OVERLAY WITH RHMA GAP GRADED. |
| Location Description | SAN DIEGO COUNTY NEAR PALA FROM ROUTE 76/15 SEPARATION TO PALA MISSION ROAD |
| QA Service Level | 1 (Verified on 06/11/2024) |
Sample Information
| Sample Taken Date | 08/14/2025 | Sample Unique Key | 87 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/15/2025 |
| Sample type | Production Start-Up | A brief description of the sample | PSU |
| The quantity of what the sample constitutes | 12 Boxes | From where was the sample collected | Supplier |
| First name of sampler or witnessed by | Gerardo | Last name of sampler or witnessed by | Cordero |
| Title of sampler | TET | Telephone number of sampler | 6199366795 |
| Laboratory sample identification | 25-08-14-87-PSU | Linked DIME Sample ID | 2025-08-14-88 |
| The fabricator/manufacturer/facility name | Martin Marietta | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | |
| Sublot number | HMA Mix Number | 23417105 MM | |
| Binder content (%) | 4.5 | Virgin binder PG | PG58-16 |
| Design binder PG | PG58-16 | Binder Supplier | Martin Marietta |
| RAP content (%) | 25 | WMA Additives | Yes |
| Antistrip type | Liquid |
Test Details
DIME Sample ID: 2025-08-14-87
DIME Test ID: 2025-08-14-87-9
Testing Lab: CT D11 - District 11 Materials Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2025-08-28
Test Results
What temperature unit is used?: Celsius
Input Type: Measured
Tester's full name: Mohammad Abbassi
Date of test: 08/28/2025
Test procedure used?: Method A
Mass of the specimen basket assembly: 3995.5 g
Mass of the specimen and specimen basket assembly prior to ignition: 5640.9 g
Mass of HMA Sample prior to ignition: 1645.4 g
Mass Loss: 121.3 g
Mass of aggregate remaining after ignition: 1524.1 g
Correction Factor (Percent by mass of HMA Specimen): 0.00 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.00 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 7.37 %
General comments (publicly viewable) (Max 1000 characters): 3 RAP burns, save 1 for gradation
Test was verified on 8/28/2025 ✔