Summary for Test 2025-08-20-56-1
Test performed: AASHTO T308-10Project Information
| Project Identifiers | Project ID: 995026 DEA: 040Q1004 EFIS: 0418000044 |
|---|---|
| DIST-CO-RTE-PM | 04-ALA-580-20.7/30.8 |
| Award Date | 07/11/2024 |
| Closeout Date | Not set |
| Work Description | REHAB ALA 580 |
| Location Description | ALAMEDA COUNTY IN PLEASANTON AND CASTRO VALLEY FROM ROUTE 680/580 SEPARATION TO ROUTE 580/238 SEPARATION |
| QA Service Level | 1 (Verified on 07/28/2023) |
Sample Information
| Sample Taken Date | 08/20/2025 | Sample Unique Key | 56 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/21/2025 |
| Sample type | Quality Assurance | A brief description of the sample | 3/4"HMA w/25% RAP |
| The quantity of what the sample constitutes | 750 Tons | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Scott | Last name of sampler or witnessed by | Sowko |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Vulcan Pleasanton | Transportation Laboratory (TL) Number | CPL082025 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | 1 |
| Sublot number | 9 | HMA Mix Number | 220304 |
| Binder content (%) | 4.7 | Virgin binder PG | PG 58-22 |
| Design binder PG | PG 58-22 | Binder Supplier | |
| RAP content (%) | Not set | WMA Additives | Yes |
| Antistrip type |
Test Details
DIME Sample ID: 2025-08-20-56
DIME Test ID: 2025-08-20-56-1
Testing Lab: CT D04 - Pleasanton Field Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2025-08-27
Test Results
What temperature unit is used?: Celsius
Input Type: Measured
Tester's full name: Dennis Yeung
Date of test: 08/26/2025
Test procedure used?: Method A
Mass of the specimen basket assembly: 2881.0 g
Mass of the specimen and specimen basket assembly prior to ignition: 4897.4 g
Mass of HMA Sample prior to ignition: 2016.4 g
Mass Loss: 129.8 g
Mass of aggregate remaining after ignition: 1886.6 g
Correction Factor (Percent by mass of HMA Specimen): 1.49 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.15 %
Test Temperature: 482 C
Corrected Asphalt Binder Content: 4.80 %
General comments (publicly viewable) (Max 1000 characters): Lot 1 SL 9
Test was verified on 8/27/2025 ✔