Summary for Test 2025-07-30-1-3

Test performed: ASTM F606-21

Project Information

Project IdentifiersProject ID: 993595
DEA: 042Q5504
EFIS: 0419000024
DIST-CO-RTE-PM04-SOL-12-7.9/14.1
Award Date02/14/2025
Closeout DateNot set
Work DescriptionRHMA OVERLAY, REPLACE CULVERTS, BRIDGE RAILS, AND MEDIAN BARRIERS.
Location DescriptionSOLANO COUNTY NEAR SUISUN CITY FROM 0.2 MILE EAST OF LAWLER RANCH PARKWAY TO 0.5 MILE EAST OF SHILOH ROAD
QA Service Level1 (Verified on 02/22/2022)

Sample Information

Sample Taken Date07/30/2025 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing08/05/2025
Sample typeVerification A brief description of the sampleF1544 Gr 105 Heavy Hex Bolt
The quantity of what the sample constitutes28 From where was the sample collectedFabricator
First name of sampler or witnessed byChris Last name of sampler or witnessed byDsouza
Title of sampler Telephone number of sampler9493852715
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameUniveral Industrial Sales Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)
Heat Number(s)58063033-07 Nut Mfg. Lot Number(s)NA
Washer Mfg. Lot Number(s) Bolt SpecificationASTM F1544 Grade 105
Bolt Length(s)20" Nut SpecificationNA
Washer SpecificationNA FinishHot Dip Galvanized
Diameter/Size1 1/4" Bolt Mfg. Lot Number65325
Rocap Test Requirement(s) Lubricant Requirements(s)
Washer Inner Diameter(s)

Test Details

DIME Sample ID: 2025-07-30-1
DIME Test ID: 2025-07-30-1-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2025-08-26

Test Results


Number of Bolt Samples: 1
Input Type: Measured
Tester's full name: Steven Paine
Date of test: 08/26/2025
UTM: NA
Temperature: 0 f
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)Wedge Angle (deg)CommentsTested By
11A58063033-071.2512938000000000yield 123540WSP

General comments (publicly viewable) (Max 1000 characters):

Test was verified on 8/26/2025