Summary for Test 2025-07-22-43-4
Test performed: ASTM C39-21Project Information
| Project Identifiers | Project ID: 1000279 DEA: 023H70U4 EFIS: 0223000161 |
|---|---|
| DIST-CO-RTE-PM | 02-TRI-299-15.0/25.7 |
| Award Date | 08/09/2024 |
| Closeout Date | Not set |
| Work Description | RHMA-G, HMA (TYPE A), COLD PLANE AC, & SOLDIER PILE RETAINING WALL. |
| Location Description | TRINITY COUNTY NEAR DEL LOMA FROM 1.0 MILE EAST OF TRINITY RIVER BRIDGE NO.05-0006 TO 0.1 MILE WEST OF PRAIRIE CREEK ROAD |
| QA Service Level | 1 (Verified on 04/30/2024) |
Sample Information
| Sample Taken Date | 07/22/2025 | Sample Unique Key | 43 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/22/2025 |
| Sample type | Quality Control | A brief description of the sample | 9 4x8 concrete cylinders |
| The quantity of what the sample constitutes | 1 CU/FT | From where was the sample collected | Supplier |
| First name of sampler or witnessed by | Donald | Last name of sampler or witnessed by | Juneman |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | JF Shea Construction, Shasta Redi-Mix, Redding, CA | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | CT752SLA50 |
|---|---|---|---|
| The truck number from where the sample was collected | The batch plant ticket number from where the sample was collected | 99453 | |
| Concrete batch plant | The fabricator/manufacturer designation for the sample | ||
| A detailed description of where the material sample was collected | Back of Truck | Where the material sample would have been placed if not sampled | |
| From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2025-07-22-43
DIME Test ID: 2025-07-22-43-4
Testing Lab: Precast Unlimited Inc.
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2025-08-25
Test Results
Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Calculated
Tester's full name: Donald Juneman
Date of test: 08/19/2025
Capped in accordance with?: ASTM C1231 - Unbonded Elastomeric Pad Cap
Apparent mass of submerged cylinder 1: 8.5 lb
Average diameter of cylinder 1: 4.00 in
Average diameter of cylinder 2: 4.00 in
Average diameter of cylinder 3: 4.00 in
Maximum load on cylinder 1: 71570 lb
Maximum load on cylinder 2: 72210 lb
Maximum load on cylinder 3: 69800 lb
Type of fracture pattern of cylinder 1: 3
Type of fracture pattern of cylinder 2: 3
Type of fracture pattern of cylinder 3: 5
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Correction factor for cylinder 3: 1.00
Age of specimen: 28 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 12.56 in^2
Cross sectional area of cylinder 2: 12.56 in^2
Cross sectional area of cylinder 3: 12.56 in^2
Compressive strength (to nearest 10 psi): 5660 psi
Serial number of delivery ticket, if available: no data
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 8/25/2025 ✔