Summary for Test 2025-08-05-69-2

Test performed: AASHTO T240-23

Project Information

Project IdentifiersProject ID: 1001001
DEA: 081N7704
EFIS: 0823000047
DIST-CO-RTE-PM08-SBD-173-L0.0/L7.7
Award Date04/25/2025
Closeout DateNot set
Work DescriptionCOLD PLANE AC PVMT, HMA (TYPE A), AND REPLACE AC SURFACING.
Location DescriptionSAN BERNARDINO COUNTY IN HESPERIA FROM ROUTE 138 TO 0.5 MILE EAST OF ARROWHEAD LAKE ROAD
QA Service Level1 (Verified on 04/07/2025)

Sample Information

Sample Taken Date08/05/2025 Sample Unique Key69
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/06/2025
Sample typeVerification A brief description of the sampleAsphalt Binder Sample
The quantity of what the sample constitutes1can From where was the sample collectedSource
First name of sampler or witnessed byFRANCISO Last name of sampler or witnessed byRUVALCABA
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameVULCA-ORO GRANDE Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeAsphalt Binder Performance GradePG 58-22
Modified Lot number
Sublot number Tank number
Time of sample HMA Supplier
Certified Asphalt SupplierValero Marketing & Supply - Wilmington CA MultigradeNo
Multigrade Type Asphalt Binder Mix Number

Test Details

DIME Sample ID: 2025-08-05-69
DIME Test ID: 2025-08-05-69-2
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T240-23: Standard Method of Test for Effect of Heat and Air on a Moving Film of Asphalt Binder (Rolling Thin-Film Oven Test)
Test Release Date: 2025-10-08

Test Results


Is mass change based on one or two containers?: Two
Is mass change correction factor needed?: Yes
Input Type: Measured
Tester's full name: Angelito Villegas
Date of test: 08/13/2025
Any material loss from containers during heating process/testing?: No
Mass of container #1 before test (m1i): 203.527 grams
Mass of container #2 before test (m2i): 206.489 grams
Mass of container #1 after test (m1f): 203.256 grams
Mass of container #2 after test (m2f): 206.224 grams
Mass of empty container #1: 168.838 grams
Mass of empty container #2: 171.472 grams
Mass correction factor: 0.006
Average mass change: -0.763 percent
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 10/8/2025