Summary for Test 2025-07-15-126-1
Test performed: AASHTO T308-10Project Information
| Project Identifiers | Project ID: 994051 DEA: 041Q5814 EFIS: 0421000262 |
|---|---|
| DIST-CO-RTE-PM | 04-SM-101-0.0-6.5 |
| Award Date | 01/10/2024 |
| Closeout Date | Not set |
| Work Description | REHABILITATE PAVEMENT AND UPGRADE MEDIAN BARRIER [PS&E E-COPY AVAILABLE UPON REQUEST] |
| Location Description | SAN MATEO COUNTY FROM SAN MATEO COUNTY LINE IN EAST PALO ALTO TO WHIPPLE AVENUE IN REDWOOD CITY |
| QA Service Level | 1 (Verified on 07/05/2022) |
Sample Information
| Sample Taken Date | 07/15/2025 | Sample Unique Key | 126 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/16/2025 |
| Sample type | Quality Assurance | A brief description of the sample | 1/2" RHMA-O WMA |
| The quantity of what the sample constitutes | 0 to 750 Tons | From where was the sample collected | Source |
| First name of sampler or witnessed by | Hollie | Last name of sampler or witnessed by | Sada |
| Title of sampler | QC Tech | Telephone number of sampler | |
| Laboratory sample identification | SJ-071525-1-T308-A | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | Vulcan Pleasanton Drier Drum Plant | Transportation Laboratory (TL) Number | SJ-071525-1 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | OGFC |
|---|---|---|---|
| HMA Grading | 1/2 inch | Lot number | 3 |
| Sublot number | 8 | HMA Mix Number | 326114W |
| Binder content (%) | 0.0 | Virgin binder PG | |
| Design binder PG | Binder Supplier | ||
| RAP content (%) | Not set | WMA Additives | |
| Antistrip type |
Test Details
DIME Sample ID: 2025-07-15-126
DIME Test ID: 2025-07-15-126-1
Testing Lab: CT D04 - San Jose Construction Field Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2025-08-26
Test Results
What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Jacob Vega
Date of test: 07/16/2025
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 1672.1 g
Mass Loss: 149.4 g
Correction Factor (Percent by mass of HMA Specimen): 0.85 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.21 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 7.87 %
General comments (publicly viewable) (Max 1000 characters): Lot 3 Sublot 8
Test was verified on 8/26/2025 ✔