Summary for Test 2025-07-15-126-1

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 994051
DEA: 041Q5814
EFIS: 0421000262
DIST-CO-RTE-PM04-SM-101-0.0-6.5
Award Date01/10/2024
Closeout DateNot set
Work DescriptionREHABILITATE PAVEMENT AND UPGRADE MEDIAN BARRIER [PS&E E-COPY AVAILABLE UPON REQUEST]
Location DescriptionSAN MATEO COUNTY FROM SAN MATEO COUNTY LINE IN EAST PALO ALTO TO WHIPPLE AVENUE IN REDWOOD CITY
QA Service Level1 (Verified on 07/05/2022)

Sample Information

Sample Taken Date07/15/2025 Sample Unique Key126
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/16/2025
Sample typeQuality Assurance A brief description of the sample1/2" RHMA-O WMA
The quantity of what the sample constitutes0 to 750 Tons From where was the sample collectedSource
First name of sampler or witnessed byHollie Last name of sampler or witnessed bySada
Title of samplerQC Tech Telephone number of sampler
Laboratory sample identificationSJ-071525-1-T308-A Linked DIME Sample ID
The fabricator/manufacturer/facility nameVulcan Pleasanton Drier Drum Plant Transportation Laboratory (TL) NumberSJ-071525-1
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeOGFC
HMA Grading1/2 inch Lot number3
Sublot number8 HMA Mix Number326114W
Binder content (%)0.0 Virgin binder PG
Design binder PG Binder Supplier
RAP content (%)Not set WMA Additives
Antistrip type

Test Details

DIME Sample ID: 2025-07-15-126
DIME Test ID: 2025-07-15-126-1
Testing Lab: CT D04 - San Jose Construction Field Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2025-08-26

Test Results


What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Jacob Vega
Date of test: 07/16/2025
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 1672.1 g
Mass Loss: 149.4 g
Correction Factor (Percent by mass of HMA Specimen): 0.85 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.21 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 7.87 %
General comments (publicly viewable) (Max 1000 characters): Lot 3 Sublot 8

Test was verified on 8/26/2025