Summary for Test 2025-08-05-81-2
Test performed: CTM 301-March 2000Project Information
| Project Identifiers | Project ID: 215734 DEA: 024H0104 EFIS: 0218000068 |
|---|---|
| DIST-CO-RTE-PM | 02-PLU-70-78.3/90.3 |
| Award Date | 01/29/2025 |
| Closeout Date | Not set |
| Work Description | REPLACE AC SURFACING, PLACE HMA AND THERMOPLASTIC TRAFFIC STRIPING. |
| Location Description | PLUMAS COUNTY NEAR PORTOLA FROM 0.4 MILE WEST OF BIG GRIZZLY CREEK BRIDGE TO 0.8 MILE WEST OF SUMMIT SCHOOL DRIVE |
| QA Service Level | 1 (Verified on 07/08/2021) |
Sample Information
| Sample Taken Date | 08/05/2025 | Sample Unique Key | 81 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/08/2025 |
| Sample type | Acceptance | A brief description of the sample | Subgrade |
| The quantity of what the sample constitutes | 2 Bags | From where was the sample collected | Source |
| First name of sampler or witnessed by | Riley | Last name of sampler or witnessed by | Melvin |
| Title of sampler | Consultant | Telephone number of sampler | |
| Laboratory sample identification | D79990 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | In Situ | Transportation Laboratory (TL) Number | 972014 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Soil | The fabricator's/manufacturer's product name for the sample | |
|---|---|---|---|
| The fabricator/manufacturer designation for the sample | A detailed description of where the material sample was collected | St. 111+68 to St. 112+34 | |
| Where the material sample would have been placed if not sampled |
Test Details
DIME Sample ID: 2025-08-05-81
DIME Test ID: 2025-08-05-81-2
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: CTM 301-March 2000: Method for Determining the Resistance "R" Value of Treated and Untreated Bases, Subbases, and Basement Soils by the Stabilometer
Test Release Date: 2025-08-21
Test Results
How will the R value be determined?: By stabilometer
Input Type: Measured
Tester's full name: Colt Sweeny
Date of test: 08/20/2025
As Received Gradation, Percent Passing 3 in. sieve: no data
As Received Gradation, Percent Passing 2 1/2 in. sieve: no data
As Received Gradation, Percent Passing 2 in. sieve: no data
As Received Gradation, Percent Passing 1 1/2 in. sieve: no data
As Received Gradation, Percent Passing 1 in. sieve: 100 %
As Received Gradation, Percent Passing 3/4 in. sieve: 99 %
As Received Gradation, Percent Passing 1/2 in. sieve: 96 %
As Received Gradation, Percent Passing 3/8 in. sieve: 93 %
As Received Gradation, Percent Passing #4 sieve: 90 %
As Received Gradation, Percent Passing #8 sieve: 85 %
As Received Gradation, Percent Passing #16 sieve: 80 %
As Received Gradation, Percent Passing #30 sieve: 76 %
As Received Gradation, Percent Passing #50 sieve: 67 %
As Received Gradation, Percent Passing #100 sieve: 54 %
As Received Gradation, Percent Passing #200 sieve: 41 %
As Used Gradation, Percent Passing 3 in. sieve: no data
As Used Gradation, Percent Passing 2 1/2 in. sieve: no data
As Used Gradation, Percent Passing 2 in. sieve: no data
As Used Gradation, Percent Passing 1 1/2 in. sieve: no data
As Used Gradation, Percent Passing 1 in. sieve: 100 %
As Used Gradation, Percent Passing 3/4 in. sieve: 100 %
As Used Gradation, Percent Passing 1/2 in. sieve: 97 %
As Used Gradation, Percent Passing 3/8 in. sieve: 91 %
As Used Gradation, Percent Passing #4 sieve: 90 %
As Used Gradation, Percent Passing #8 sieve: 85 %
As Used Gradation, Percent Passing #16 sieve: 81 %
As Used Gradation, Percent Passing #30 sieve: 76 %
As Used Gradation, Percent Passing #50 sieve: 68 %
As Used Gradation, Percent Passing #100 sieve: 54 %
As Used Gradation, Percent Passing #200 sieve: 42 %
Horizontal pressure (specimen 1): 0.8 MPa
Displacement (specimen 1): 3.74
Horizontal pressure (specimen 2): 0.95 MPa
Displacement (specimen 2): 4.08
Horizontal pressure (specimen 3): 0.98 MPa
Displacement (specimen 3): 4.52
R value (specimen 1): 20
R value (specimen 2): 8.8
R value (specimen 3): 6.3
R value: 7
General comments (publicly viewable) (Max 1000 characters): R=7
Test was verified on 8/21/2025 ✔