Summary for Test 2025-05-29-126-2

Test performed: CTM 216-June 2011

Project Information

Project IdentifiersProject ID: 994469
DEA: 044J89U4
EFIS: 0419000140
COOP: 042806
DIST-CO-RTE-PM04-SCL-82-18.2/26.4
Award Date08/17/2023
Closeout DateNot set
Work DescriptionCOLD PLANE AC, RHMA, SLAB REPL, CURB RAMPS, AND MOD ELECT SYSTEMS.
Location DescriptionSANTA CLARA COUNTY AT VARIOUS LOCATIONS FROM KNICKERBOCKER DRIVE IN SUNNYVALE TO SAN MATEO COUNTY LINE IN PALO ALTO
QA Service Level1 (Verified on 05/09/2023)

Sample Information

Sample Taken Date05/29/2025 Sample Unique Key126
Date that the sample was received by the laboratory/organization performing the testing05/29/2025 Sample typeQuality Assurance
A brief description of the sampleRecycled Aggregate Backfill The quantity of what the sample constitutes2600g
From where was the sample collectedJob Site First name of sampler or witnessed byJacob
Last name of sampler or witnessed byVega Title of samplerMozamo Consultant QA
Telephone number of sampler Laboratory sample identificationSJ-052925-AB1
Linked DIME Sample ID The fabricator/manufacturer/facility nameStevens Creek Quarry
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure nameHwy 82 NB Rt "A1" Line Backfill Electric Conduit
Bid ItemNot set

Material Information

Material TypeSoil The fabricator's/manufacturer's product name for the sample
The fabricator/manufacturer designation for the sample A detailed description of where the material sample was collectedJobsite - Compacted Aggregate Backfill
Where the material sample would have been placed if not sampled

Test Details

DIME Sample ID: 2025-05-29-126
DIME Test ID: 2025-05-29-126-2
Testing Lab: CT D04 - San Jose Construction Field Laboratory
Test Method: CTM 216-June 2011: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates
Test Release Date: 2025-08-21

Test Results


Is oversize material: No
Input Type: Calculated
Tester's full name: Jacob Vega
Date of test: 05/29/2025
In-place wet density: 2.03
Highest adjust wet density: 2.14
% Moisture: no data
Optimum Moisture: no data
Relative compaction: 95
General comments (publicly viewable) (Max 1000 characters): Backfill Electric Conduit

Test was verified on 8/21/2025 ✔