Summary for Test 2025-08-13-66-1

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 995254
DEA: 040P9204
EFIS: 0418000026
DIST-CO-RTE-PM04-ALA-680-6.4/6.6
Award Date12/20/2024
Closeout DateNot set
Work DescriptionHMA AND RHMA SURFACING, DECK REPAIR, POLYESTER OVERLAY AND JOIN SEALS
Location DescriptionALAMEDA COUNTY IN FREMONT FROM 0.1 MILE SOUTH OF MISSION SAN JOSE 680/238 SEPARATION TO 0.3 MILE NORTH OF MISSION SAN JOSE 680/238 SEPARATION
QA Service Level1 (Verified on 10/17/2023)

Sample Information

Sample Taken Date08/13/2025 Sample Unique Key66
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/14/2025
Sample typeQuality Assurance A brief description of the sample1/2"RHMA-O
The quantity of what the sample constitutes750 Tons From where was the sample collectedJob Site
First name of sampler or witnessed byScott Last name of sampler or witnessed bySowko
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameVulcan Pleasanton Transportation Laboratory (TL) NumberCPL081325
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeOGFC
HMA Grading1/2 inch Lot number1
Sublot number2 HMA Mix Number326114W
Binder content (%)7.8 Virgin binder PG PG 64-16
Design binder PG PG 64-16 Binder Supplier
RAP content (%)Not set WMA AdditivesYes
Antistrip type

Test Details

DIME Sample ID: 2025-08-13-66
DIME Test ID: 2025-08-13-66-1
Testing Lab: CT D04 - Pleasanton Field Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2025-08-21

Test Results


What temperature unit is used?: Celsius
Input Type: Measured
Tester's full name: Robert Lohman
Date of test: 08/21/2025
Test procedure used?: Method A
Mass of the specimen basket assembly: 2930.3 g
Mass of the specimen and specimen basket assembly prior to ignition: 4440.9 g
Mass of HMA Sample prior to ignition: 1510.6 g
Mass Loss: 130.8 g
Mass of aggregate remaining after ignition: 1379.8 g
Correction Factor (Percent by mass of HMA Specimen): 0.22 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.20 %
Test Temperature: 482 C
Corrected Asphalt Binder Content: 8.24 %
General comments (publicly viewable) (Max 1000 characters): Lot 1 SL 2

Test was verified on 8/21/2025