Summary for Test 2025-08-18-30-2

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 1000901
DEA: 061G8004
EFIS: 0624000167
DIST-CO-RTE-PM06-KER-99-R29.4/33.1
Award Date03/27/2025
Closeout DateNot set
Work DescriptionCOLD PLANE AC PAVEMENT, REMOVE CONCRETE PAVEMENT, AND HMA.
Location DescriptionKERN COUNTY NEAR BAKERSFIELD FROM 0.5 MILE SOUTH OF ROUTE 65/99 SEPARATION TO 0.7 MILE NORTH OF LERDO CANAL BRIDGE
QA Service Level1 (Verified on 01/22/2025)

Sample Information

Sample Taken Date08/18/2025 Sample Unique Key30
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/19/2025
Sample typeAcceptance A brief description of the sample3/4" HMA (Type A) with 15% rap
The quantity of what the sample constitutesL1SL7 From where was the sample collectedSource
First name of sampler or witnessed byQC Last name of sampler or witnessed byG3
Title of samplerMaterials Tester Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameGriffith Edmonston Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/4 inch Lot number1
Sublot number7 HMA Mix Number24J013
Binder content (%)4.7 Virgin binder PG PG 70-10
Design binder PG PG 70-10 Binder SupplierSan Juaquin Refinery
RAP content (%)15 WMA Additives
Antistrip type1.0% Lime

Test Details

DIME Sample ID: 2025-08-18-30
DIME Test ID: 2025-08-18-30-2
Testing Lab: CT D06 - Bakersfield Field Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2025-08-19

Test Results


What temperature unit is used?: Fahrenheit
Input Type: Measured
Tester's full name: Neale
Date of test: 08/19/2025
Test procedure used?: Method A
Mass of the specimen basket assembly: 3964.8 g
Mass of the specimen and specimen basket assembly prior to ignition: 6040.4 g
Mass of HMA Sample prior to ignition: 2075.6 g
Mass Loss: 105.8 g
Mass of aggregate remaining after ignition: 1969.8 g
Correction Factor (Percent by mass of HMA Specimen): 0.44 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.00 %
Test Temperature: 538 F
Corrected Asphalt Binder Content: 4.66 %
General comments (publicly viewable) (Max 1000 characters):

Test File Attachments

File NameExtensionFile SizeDate UploadedTest IDActions
06-1G8004_37014_250818_T308_L1SL7pdf83.51 KB08/19/20252025-08-18-30-2   Info

Test was verified on 8/19/2025