Summary for Test 2025-08-04-63-6
Test performed: CTM 389-19Project Information
| Project Identifiers | Project ID: 1001099 DEA: 112N1784 EFIS: 1123000070 |
|---|---|
| DIST-CO-RTE-PM | 11-IMP-8-R0.0R/R10.3 |
| Award Date | 05/29/2025 |
| Closeout Date | Not set |
| Work Description | MICRO-SURFACING, COLD PLANE AC PAVEMENT, PLACE HMA, AND STRIPING. |
| Location Description | IMPERIAL COUNTY FROM IMPERIAL COUNTY LINE (R0.0R) TO 98/8 FLYOVER (R10.3) AND 98/8 INTERCHANGE |
| QA Service Level | 1 (Verified on 05/30/2025) |
Sample Information
| Sample Taken Date | 08/04/2025 | Sample Unique Key | 63 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 08/11/2025 | Sample type | Verification |
| A brief description of the sample | JMFV | The quantity of what the sample constitutes | 12 boxes |
| From where was the sample collected | Supplier | First name of sampler or witnessed by | Gerardo |
| Last name of sampler or witnessed by | Cordero | Title of sampler | TET |
| Telephone number of sampler | 6199366795 | Laboratory sample identification | 25-08-04-63-JMFR |
| Linked DIME Sample ID | 2025-08-04-64 | The fabricator/manufacturer/facility name | API Gateway |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | |
| Sublot number | HMA Mix Number | 2 API | |
| Binder content (%) | 4.5 | Virgin binder PG | PG 70-10 |
| Design binder PG | PG 70-10 | Binder Supplier | Valero |
| RAP content (%) | 0 | WMA Additives | No |
| Antistrip type | - |
Test Details
DIME Sample ID: 2025-08-04-63
DIME Test ID: 2025-08-04-63-6
Testing Lab: CT D11 - District 11 Materials Laboratory
Test Method: CTM 389-19: Method of Test for Hamburg Wheel-Track Testing of Compacted Hot Mix Asphalt
Test Release Date: 2025-08-19
Test Results
Specified number of passes at 12.7 mm: 20000
Specimen Preparation Method: PMLC
Input Type: Measured
Tester's full name: Daniel Smith
Date of test: 08/15/2025
Test Temperature: 55 F
Compaction Method: SGC Cylindrical Specimen
Air Void Content for specimen A-1: no data
Air Void Content for specimen A-2: no data
Air Void Content for specimen B-1: no data
Air Void Content for specimen B-2: no data
Stripping Inflection Point (Wheel A): >20000
Stripping Inflection Point (Wheel B): >20000
Maximum impression at 5000 passes (left wheel): 1.52 mm
Maximum impression at 5000 passes (right wheel): 0.82 mm
Average impression at 5000 passes (left/right avg): 1.17 mm
Maximum impression at 10000 passes (left wheel): 1.64 mm
Maximum impression at 10000 passes (right wheel): 1.12 mm
Average impression at 10000 passes (left/right avg): 1.38 mm
Maximum impression at 15000 passes (left wheel): 1.74 mm
Maximum impression at 15000 passes (right wheel): 1.4 mm
Average impression at 15000 passes (left/right avg): 1.57 mm
Maximum impression at 20000 passes (left wheel): 1.87 mm
Maximum impression at 20000 passes (right wheel): 1.6 mm
Average impression at 20000 passes (left/right avg): 1.74 mm
Maximum impression at 25000 passes (left wheel): no data
Maximum impression at 25000 passes (right wheel): no data
Average impression at 25000 passes (left/right avg): no data
Raw Data: excel
General comments (publicly viewable) (Max 1000 characters): Complies Target - 12.7 MM Tested an Avg of 1.74 mm
Test was verified on 8/19/2025 ✔