Summary for Test 2017-10-17-7-1
Test performed: AGGLP SIEVE_ANALYSIS-1Project Information
| Project Identifiers | Project ID: 212824 DEA: 051C3704 EFIS: 0512000135 |
|---|---|
| DIST-CO-RTE-PM | 05-SLO-101-16.4 |
| Award Date | 11/20/2018 |
| Closeout Date | 08/23/2021 |
| Work Description | PISMO CREEK SCOUR REPAIR PROJECT (BR 49-0015K) |
| Location Description | IN SAN LUIS OBISPO COUNTY IN PISMO AT PISMO CREEK BRIDGE |
| QA Service Level | 1 (Verified on 01/29/2019) |
Sample Information
| Sample Taken Date | 10/17/2017 | Sample Unique Key | 7 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/24/2017 |
| Sample type | Quality Control | A brief description of the sample | Pismo Creek Bridge 49-0015K |
| The quantity of what the sample constitutes | 1 bag | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Joe | Last name of sampler or witnessed by | Pratt |
| Title of sampler | Unknown | Telephone number of sampler | Unknown |
| Laboratory sample identification | 17SOIL-0321 | Linked DIME Sample ID | Unknown |
| The fabricator/manufacturer/facility name | NA | Transportation Laboratory (TL) Number | CJP2017-1A |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | Not set |
| Structure name | Not set | Bid Item | Not set |
Material Information
| Material Type | Soil | The fabricator's/manufacturer's product name for the sample | Unknown |
|---|---|---|---|
| The fabricator/manufacturer designation for the sample | Unknown | A detailed description of where the material sample was collected | RC-17-005 |
| Where the material sample would have been placed if not sampled | 16 to 18 ft |
Test Details
DIME Sample ID: 2017-10-17-7
DIME Test ID: 2017-10-17-7-1
Testing Lab: CT HQ - Sacramento Aggregate Testing Laboratory
Test Method: AGGLP SIEVE_ANALYSIS-1: Soils for Corrosion Sieve Analysis
Test Release Date: 2017-11-15
Test Results
Input Type: Measured
Tester's full name: Phillip Montes
Date of test: 11/15/2017
Total mass of material in the sample: 1460.0 grams
Cumulative mass retained on the 2 in. sieve: 0.0 grams
Cumulative mass retained on the 1 1/2 in. sieve: 0.0 grams
Cumulative mass retained on the 1 in. sieve: 0.0 grams
Cumulative mass retained on the 3/4 in. sieve: 0.0 grams
Cumulative mass retained on the 1/2 in. sieve: 0.0 grams
Cumulative mass retained on the 3/8 in. sieve: 0.0 grams
Cumulative mass retained on the #4 sieve: 1.0 grams
Cumulative mass retained on the #8 sieve: 1.0 grams
Total sample mass passing the #4 sieve: 721 grams
Total mass of fine material in the sample: 542 grams
Cumulative mass retained on the pan: 541.0 grams
Total cumulative mass of coarse aggregate: 1 grams
Total cumulative mass of fine aggregate: 542 grams
Sum of coarse and fine aggregate: 722
Percentage of coarse material: 0 %
Percentage of fine material: 100 %
Cumulative percent passing the 2 in. sieve: 100 %
Cumulative percent passing the 1 1/2 in. sieve: 100 %
Cumulative percent passing the 1 in. sieve: 100 %
Cumulative percent passing the 3/4 in. sieve: 100 %
Cumulative percent passing the 1/2 in. sieve: 100 %
Cumulative percent passing the 3/8 in. sieve: 100 %
Cumulative percent passing the #4 sieve: 100 %
Cumulative percent passing the #8 sieve: 100 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 11/15/2017 ✔