Summary for Test 2017-11-09-11-3
Test performed: ASTM A970-15e1Project Information
| Project Identifiers | Project ID: 208945 DEA: 07288604 EFIS: 0700021080 COOP: 074663 |
|---|---|
| DIST-CO-RTE-PM | 07-LA-710-6.0-9.4 |
| Award Date | 09/02/2011 |
| Closeout Date | Not set |
| Work Description | Gerald Desmond Bridge Replacement - A Design Build project. IQA samples will be selected by Port/Caltrans representatives and sent to Translab for testing. |
| Location Description | Port of Long Beach (District 7) |
| QA Service Level | 1 (Verified on 06/03/2013) |
Sample Information
| Sample Taken Date | 11/09/2017 | Sample Unique Key | 11 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 11/15/2017 | Sample type | Quality Assurance |
| A brief description of the sample | HRC T-Heads | The quantity of what the sample constitutes | 150 |
| From where was the sample collected | Fabricator | First name of sampler or witnessed by | Russell |
| Last name of sampler or witnessed by | Lynch | Title of sampler | QAI |
| Telephone number of sampler | Unknown | Laboratory sample identification | Unknown |
| Linked DIME Sample ID | Unknown | The fabricator/manufacturer/facility name | CMC Rebar Etiwanda |
| Transportation Laboratory (TL) Number | C939724 | Inspector Lot Number from the Transportation Laboratory (TL) Form | L96-208-17 |
| Structure unique identifier | Not set | Structure name | Not set |
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Headed Bars | Production or Authorization Testing | Production Testing |
|---|---|---|---|
| Rebar Heat Number(s) | 4070582 | Head Manufacturer Lot Number(s) | 1000 |
| Rebar Size | #7 | Headed Bar Model Name | HRC 555 |
| Size of Head | Full Size - 9x | Head Connection Type | Forged |
| Head Shape | Circular | Rebar Manufacturer | CMC Rebar |
| Head Manufacturer | HRC | Head Fabricator | HRC |
| Material Standard Code | ASTM A706 | Headed Bar Unique ID | Not set |
Test Details
DIME Sample ID: 2017-11-09-11
DIME Test ID: 2017-11-09-11-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Test Release Date: 2017-11-23
Test Results
Number of Headed Bar Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 11/15/2017
UTM: 400KIP
Temperature: 72 F
| Num | Lot # | Area (sqin) | Peak Load (lbf) | Tensile Strength (psi) | Comments | Tested By |
|---|---|---|---|---|---|---|
| 1 | 1 | 0.6 | 55560 | 92600 | Bar Broke Head off | Fred |
General comments (publicly viewable) (Max 1000 characters): Bar Broke Head off
Test Graph
Source: Partner Data Point FileTest graph for the Sample
Test was verified on 11/16/2017 ✔