Summary for Test 2025-08-06-68-2

Test performed: AASHTO T240-23

Project Information

Project IdentifiersProject ID: 1001001
DEA: 081N7704
EFIS: 0823000047
DIST-CO-RTE-PM08-SBD-173-L0.0/L7.7
Award Date04/25/2025
Closeout Date07/23/2026
Work DescriptionCOLD PLANE AC PVMT, HMA (TYPE A), AND REPLACE AC SURFACING.
Location DescriptionSAN BERNARDINO COUNTY IN HESPERIA FROM ROUTE 138 TO 0.5 MILE EAST OF ARROWHEAD LAKE ROAD
QA Service Level1 (Verified on 04/07/2025)

Sample Information

Sample Taken Date08/06/2025 Sample Unique Key68
Date that the sample was received by the laboratory/organization performing the testing08/08/2025 Sample typeVerification
A brief description of the sampleAsphalt Binder Sample The quantity of what the sample constitutes1can
From where was the sample collectedSource First name of sampler or witnessed byFRANCISO
Last name of sampler or witnessed byRUVALCABA Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameVULCA-ORO GRANDE
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAsphalt Binder Performance GradePG 58-22
Modified Lot number
Sublot number Tank number
Time of sample HMA Supplier
Certified Asphalt SupplierValero Marketing & Supply - Wilmington CA MultigradeNo
Multigrade Type Asphalt Binder Mix Number
HMA TypeNot set HMA Supplier Mix ID NumberNot set

Test Details

DIME Sample ID: 2025-08-06-68
DIME Test ID: 2025-08-06-68-2
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T240-23: Standard Method of Test for Effect of Heat and Air on a Moving Film of Asphalt Binder (Rolling Thin-Film Oven Test)
Test Release Date: 2025-08-15

Test Results


Is mass change based on one or two containers?: Two
Is mass change correction factor needed?: Yes
Input Type: Measured
Tester's full name: Angelito Villegas
Date of test: 08/15/2025
Any material loss from containers during heating process/testing?: Yes
Mass of container #1 before test (m1i): 203.779 grams
Mass of container #2 before test (m2i): 206.419 grams
Mass of container #1 after test (m1f): 203.517 grams
Mass of container #2 after test (m2f): 206.155 grams
Mass of empty container #1: 168.838 grams
Mass of empty container #2: 171.471 grams
Mass correction factor: 0.006
Average mass change: -0.747 percent
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 8/15/2025 ✔