Summary for Test 2025-08-13-45-2

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 1000904
DEA: 120U5804
EFIS: 1223000119
DIST-CO-RTE-PM12-ORA-55,57-12.3/17.0,11.2/18.4
Award Date03/28/2025
Closeout DateNot set
Work DescriptionAPPLY METHACRYLATE, OVERLAY POLYESTER & REPLACE JOINT SEALS.
Location DescriptionORANGE COUNTY AT VARIOUS LOCATIONS ON ROUTE 55 FROM SANTA CLARA AVENUE OVERCROSSING TO LINCOLN AVENUE UNDERCROSSING AND ON ROUTE 57 FROM CHAPMAN AVENUE UNDERCROSSING TO YORBA LINDA BOULEVARD OVERCROSSING
QA Service Level1 (Verified on 01/23/2025)

Sample Information

Sample Taken Date08/13/2025 Sample Unique Key45
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/13/2025
Sample typeQuality Assurance A brief description of the sample1/2 RHMAG
The quantity of what the sample constitutes1/2 RHMAG From where was the sample collectedManufacturer
First name of sampler or witnessed byJimmy Last name of sampler or witnessed byPham
Title of sampler Telephone number of sampler
Laboratory sample identification25-0820 Linked DIME Sample ID
The fabricator/manufacturer/facility nameAAA Corona Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeRHMA-G
HMA Grading1/2 inch Lot number
Sublot number HMA Mix Number
Binder content (%)0.0 Virgin binder PG
Design binder PG Binder Supplier
RAP content (%)Not set WMA Additives
Antistrip type

Test Details

DIME Sample ID: 2025-08-13-45
DIME Test ID: 2025-08-13-45-2
Testing Lab: CT D12 - Huntington Beach Field Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2025-08-19

Test Results


What temperature unit is used?: Celsius
Input Type: Measured
Tester's full name: David Nguyen
Date of test: 08/14/2025
Test procedure used?: Method A
Mass of the specimen basket assembly: 3889.1 g
Mass of the specimen and specimen basket assembly prior to ignition: 5405.8 g
Mass of HMA Sample prior to ignition: 1516.7 g
Mass Loss: 115.2 g
Mass of aggregate remaining after ignition: 1401.5 g
Correction Factor (Percent by mass of HMA Specimen): -0.20 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.00 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 7.80 %
General comments (publicly viewable) (Max 1000 characters):

Test File Attachments

File NameExtensionFile SizeDate UploadedTest IDActions
2025AC-SP-0062pdf104.75 KB08/14/20252025-08-13-45-2   Info

Test was verified on 8/19/2025