Summary for Test 2025-07-24-52-6

Test performed: SCAQMD 309-91-Feb93

Project Information

Project IdentifiersProject ID: 210978
DEA: 020H3604
EFIS: 0215000057
DIST-CO-RTE-PM02-TEH-5,32-VAR
Award Date01/06/2016
Closeout Date06/28/2017
Work DescriptionBRIDGE MAINTENANCE
Location DescriptionBRIDGE MAINTENANCE
QA Service Level1 (Verified on 02/17/2016)

Sample Information

Sample Taken Date07/24/2025 Sample Unique Key52
Date that the sample was received by the laboratory/organization performing the testing07/28/2025 Sample typeQuality Control
A brief description of the sample1 gallon can / PPC 1121 RESIN The quantity of what the sample constitutes34 Totes
From where was the sample collectedSource First name of sampler or witnessed byGilberto
Last name of sampler or witnessed byGonzalez Title of samplerQuality Control Manager
Telephone number of sampler7076245467 Laboratory sample identification000171KBP
Linked DIME Sample ID The fabricator/manufacturer/facility nameKwik Bond Polymers, Benicia
Transportation Laboratory (TL) Number25-127 Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypePolyester Mfg. Lot Number(s)AZ5G00893T
Batch NumberAZ5G00893T Mix numberAZ5G00893T

Test Details

DIME Sample ID: 2025-07-24-52
DIME Test ID: 2025-07-24-52-6
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: SCAQMD 309-91-Feb93: Determination of Static Volatile Emissions
Test Release Date: 2025-08-13

Test Results


Input Type: Measured
Tester's full name: Gilberto Gonzalez
Date of test: 07/29/2025
Diameter of lid: 153.9 mm
Room Temperature: 78 f
Tare weight: no data
Initial weight: 100.087 grams
Weight at 5 minutes: 100.051 grams
Weight at 10 minutes: 100.009 grams
Weight at 15 minutes: 99.973 grams
Weight at 20 minutes: 99.944 grams
Weight at 25 minutes: 99.908 grams
Weight at 30 minutes: 99.858 grams
Final weight: 99.86 grams
Total weight loss: 0.23 grams
Calculated radius of gallon can lid in cm: 7.695 cm
Lid Factor: 53.757 m^2
Volatile emission: 12.203 grams/m^2
General comments (publicly viewable) (Max 1000 characters): Accepted supplier's results.

Test was verified on 8/13/2025 ✔