Summary for Test 2025-07-23-94-2

Test performed: AASHTO T240-23

Project Information

Project IdentifiersProject ID: 995057
DEA: 07321604
EFIS: 0716000049
DIST-CO-RTE-PM07-LA-1-0.0/18.0
Award Date12/20/2023
Closeout DateNot set
Work DescriptionCOLD PLANE AND OVERLAY AC PAVEMENT AND UPGRADE ADA CURB RAMPS.
Location DescriptionLOS ANGELES COUNTY FROM STUDEBAKER ROAD TO PASEO DE LAS DELICIAS
QA Service Level1 (Verified on 08/08/2023)

Sample Information

Sample Taken Date07/23/2025 Sample Unique Key94
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/28/2025
Sample typeVerification A brief description of the sampleAsphalt Rubber Binder
The quantity of what the sample constitutes1can From where was the sample collectedSource
First name of sampler or witnessed byl.RILEY?RAM QC Last name of sampler or witnessed byRMA QC
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameRJ Noble, Orange CA Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeAsphalt Binder Performance GradePG 64-16
Modified Lot number
Sublot number Tank number
Time of sample HMA Supplier
Certified Asphalt SupplierLunday Thagard Company-World Oil - South Gate CA MultigradeNo
Multigrade Type Asphalt Binder Mix Number

Test Details

DIME Sample ID: 2025-07-23-94
DIME Test ID: 2025-07-23-94-2
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T240-23: Standard Method of Test for Effect of Heat and Air on a Moving Film of Asphalt Binder (Rolling Thin-Film Oven Test)
Test Release Date: 2025-08-12

Test Results


Is mass change based on one or two containers?: Two
Is mass change correction factor needed?: Yes
Input Type: Measured
Tester's full name: Angelito Villegas
Date of test: 08/12/2025
Any material loss from containers during heating process/testing?: Yes
Mass of container #1 before test (m1i): 203.616 grams
Mass of container #2 before test (m2i): 206.179 grams
Mass of container #1 after test (m1f): 203.613 grams
Mass of container #2 after test (m2f): 206.176 grams
Mass of empty container #1: 168.839 grams
Mass of empty container #2: 171.472 grams
Mass correction factor: 0.006
Average mass change: -0.003 percent
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 8/12/2025