Summary for Test 2025-07-16-97-4
Test performed: CTM 229-June 2011Project Information
| Project Identifiers | Project ID: 1000958 DEA: 021K0704 EFIS: 0224000048 |
|---|---|
| DIST-CO-RTE-PM | 02-LAS-139-11.0/16.0 |
| Award Date | 04/09/2025 |
| Closeout Date | 12/29/2025 |
| Work Description | PERFORM PARTIAL DEPTH RECYCLING AND PLACE HOT MIX ASPHALT (TYPE A). |
| Location Description | LASSEN COUNTY ABOUT 9 MILES NORTH OF SUSANVILLE FROM 1.2 MILES SOUTH OF HAGATA ROAD TO 0.9 MILE SOUTH OF MEADOW CHANNEL BRIDGE |
| QA Service Level | 1 (Verified on 03/21/2025) |
Sample Information
| Sample Taken Date | 07/16/2025 | Sample Unique Key | 97 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 07/28/2025 | Sample type | Acceptance |
| A brief description of the sample | Shoulder backing | The quantity of what the sample constitutes | up to 3000 tons |
| From where was the sample collected | Manufacturer | First name of sampler or witnessed by | Joe |
| Last name of sampler or witnessed by | Delgado | Title of sampler | Consultant |
| Telephone number of sampler | Laboratory sample identification | D79977 | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Hat Creek Construction and Materials — Shaw Pit (Lookout, CA) | |
| Transportation Laboratory (TL) Number | 875603 | Inspector Lot Number from the Transportation Laboratory (TL) Form | |
| Structure unique identifier | Structure name | ||
| Bid Item | 3923777 |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-25-0008:: Shaw Pit (Lookout, CA) |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
| The plant number | A detailed description of where the material sample was collected | Sample Pad (Stockpile) | |
| Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 1 inch | |
| The concrete mix design number | Lot number | ||
| Sublot number | Aggregate Mix Number |
Test Details
DIME Sample ID: 2025-07-16-97
DIME Test ID: 2025-07-16-97-4
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: CTM 229-June 2011: Method of Test for Durability Index
Test Release Date: 2025-08-11
Test Results
What test(s) are being run?: Coarse durability and fine durability
Input Type: Measured
Tester's full name: Josh Murphy
Date of test: 08/05/2025
Sediment reading for coarse durability index: 53.0
Clay reading: 11.8
Sand reading: 3.5
Coarse durability index: 41
Fine durability index: 30
General comments (publicly viewable) (Max 1000 characters): DI=30
Test was verified on 8/11/2025 ✔