Summary for Test 2025-05-07-126-1

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 994226
DEA: 042K7004
EFIS: 0417000010
COOP: 042895
DIST-CO-RTE-PM04-ALA-880-R0.0/11.8
Award Date07/13/2023
Closeout DateNot set
Work DescriptionCold plane pavement and overlay with RHMA-G/RHMA-O (CAPITAL PREVENTIVE MAINTENANCE)
Location DescriptionALAMEDA COUNTY IN FREMONT AND NEWARK FROM SANTA CLARA COUNTY LINE TO 0.4 MILE NORTH OF FREMONT BOULEVARD OVERCROSSING
QA Service Level1 (Verified on 09/13/2022)

Sample Information

Sample Taken Date05/07/2025 Sample Unique Key126
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/08/2025
Sample typeQuality Assurance A brief description of the sample1/2" RHMA-G WMA
The quantity of what the sample constitutes1 to 750 Tons From where was the sample collectedManufacturer
First name of sampler or witnessed byJacob Last name of sampler or witnessed byVega
Title of samplerConsultant QA Telephone number of sampler
Laboratory sample identificationSJ-050725-MS-SA1 Linked DIME Sample ID
The fabricator/manufacturer/facility nameVulcan Pleasanton Drier Drum Plant Transportation Laboratory (TL) NumberC317-050725-1
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeRHMA-G
HMA Grading1/2 inch Lot number10
Sublot number2 HMA Mix Number326122
Binder content (%)0.0 Virgin binder PG
Design binder PG Binder Supplier
RAP content (%)Not set WMA Additives
Antistrip type

Test Details

DIME Sample ID: 2025-05-07-126
DIME Test ID: 2025-05-07-126-1
Testing Lab: CT D04 - San Jose Construction Field Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2025-08-09

Test Results


What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Jaco Vega
Date of test: 05/08/2025
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 1608.8 g
Mass Loss: 140.9 g
Correction Factor (Percent by mass of HMA Specimen): 0.99 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.22 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 7.55 %
General comments (publicly viewable) (Max 1000 characters): Lot 10 - Sublot 2, MS-T308-A

Test was verified on 8/9/2025