Summary for Test 2025-06-25-65-2
Test performed: CTM 521-June 2020Project Information
| Project Identifiers | Project ID: 1000416 DEA: 120S1104 EFIS: 1219000091 |
|---|---|
| DIST-CO-RTE-PM | 12-ORA-22-R0.9/R9.4 |
| Award Date | 09/04/2024 |
| Closeout Date | Not set |
| Work Description | REPLACE CONCRETE BARRIER AND MODIFY LIGHTING SYSTEM. |
| Location Description | ORANGE FROM BOLSA CHICA ROAD OVERCROSSING IN GARDEN GROVE TO LEWIS STREET OVERCROSSING IN ORANGE |
| QA Service Level | 1 (Verified on 08/05/2024) |
Sample Information
| Sample Taken Date | 06/25/2025 | Sample Unique Key | 65 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 06/26/2025 | Sample type | Quality Assurance |
| A brief description of the sample | 4x8 concrete cylinders | The quantity of what the sample constitutes | 6 |
| From where was the sample collected | Job Site | First name of sampler or witnessed by | Brandon |
| Last name of sampler or witnessed by | Tom | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | 25-0240 | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | National / Artesia | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | A59C456T10 |
|---|---|---|---|
| The truck number from where the sample was collected | The batch plant ticket number from where the sample was collected | Unknown | |
| Concrete batch plant | The fabricator/manufacturer designation for the sample | ||
| A detailed description of where the material sample was collected | Discharge from concrete truck into wheelbarrow. | Where the material sample would have been placed if not sampled | Barrier 60 MA Mod 173+30~174+88 |
| From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2025-06-25-65
DIME Test ID: 2025-06-25-65-2
Testing Lab: CT D12 - Huntington Beach Field Laboratory
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2025-08-06
Test Results
Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Measured
Tester's full name: Dan Morris
Date of test: 08/06/2025
Capped in accordance with?: ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1: 4.00 in
Average diameter of cylinder 2: 3.99 in
Average diameter of cylinder 3: 4.01 in
Maximum load on cylinder 1: 60240 lb
Maximum load on cylinder 2: 57620 lb
Maximum load on cylinder 3: 59220 lb
Type of fracture pattern of cylinder 1: 3
Type of fracture pattern of cylinder 2: 3
Type of fracture pattern of cylinder 3: 3
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Correction factor for cylinder 3: 1.00
Age of specimen: 42 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 12.57 in^2
Cross sectional area of cylinder 2: 12.5 in^2
Cross sectional area of cylinder 3: 12.63 in^2
Compressive strength of cylinder 1: 4792.4 psi
Compressive strength of cylinder 2: 4609.6 psi
Compressive strength of cylinder 3: 4688.8 psi
Compressive strength (to nearest 10 psi): 4700 psi
General comments (publicly viewable) (Max 1000 characters):
Test File Attachments
| File Name | Extension | File Size | Date Uploaded | Test ID | Actions |
|---|---|---|---|---|---|
| 25-0240-42D | 134.59 KB | 08/06/2025 | 2025-06-25-65-2 | Info |
Test was verified on 8/6/2025 ✔