Summary for Test 2025-08-04-20-1
Test performed: AASHTO T209-22Project Information
| Project Identifiers | Project ID: 1000943 DEA: 09404304 EFIS: 0924000070 |
|---|---|
| DIST-CO-RTE-PM | 09-MNO-120-32.1/R35.0,48.0/50.0 |
| Award Date | 04/28/2025 |
| Closeout Date | Not set |
| Work Description | COLD IN-PLACE RECYCLE EXISTING PAVEMENT AND PLACE HMA. |
| Location Description | MONO COUNTY NEAR BENTON FROM 0.5 MILE EAST TO 3.4 MILES EAST OF BAXTER\'S ROAD AND FROM 2.0 MILES WEST OF BLACK LAKE ROAD TO BLACK LAKE ROAD |
| QA Service Level | 1 (Verified on 04/07/2025) |
Sample Information
| Sample Taken Date | 08/04/2025 | Sample Unique Key | 20 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/04/2025 |
| Sample type | Production Start-Up | A brief description of the sample | 1/2" HMA-A-SP PG58-34M R25 |
| The quantity of what the sample constitutes | 750 Tons | From where was the sample collected | Source |
| First name of sampler or witnessed by | Jeff | Last name of sampler or witnessed by | Puente |
| Title of sampler | Consultant | Telephone number of sampler | |
| Laboratory sample identification | PSU-1 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | Granite Lee Vining Plant | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 1/2 inch | Lot number | |
| Sublot number | HMA Mix Number | ||
| Binder content (%) | 5.0 | Virgin binder PG | |
| Design binder PG | Binder Supplier | ||
| RAP content (%) | Not set | WMA Additives | |
| Antistrip type |
Test Details
DIME Sample ID: 2025-08-04-20
DIME Test ID: 2025-08-04-20-1
Testing Lab: CT D09 - Bishop Field Laboratory
Test Method: AASHTO T209-22: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2025-08-06
Test Results
Number of Samples: 1
What is the unit of measurement for theoretical density?: US Units
Mass Determination: Air
Input Type: Measured
Tester's full name: Derek Carrington
Date of test: 08/04/2025
Method Performed: Mechanical Agitation - Method A
Mass of container filled with water 1: 7310.5 grams
Mass of oven-dry sample in air for Sample 1: 1971.6 grams
Mass of container filled with the sample and water for Sample 1: 8482.4 grams
Temperature of Water: 77.1 °F
Specific Gravity for Sample 1: 2.465
Theoretical maximum density at 25°C (77°F): 153.4 lb/ft^3
General comments (publicly viewable) (Max 1000 characters): PSE 01
Test was verified on 8/6/2025 ✔