Summary for Test 2025-07-01-61-2

Test performed: CTM 217-June 2011

Project Information

Project IdentifiersProject ID: 1000569
DEA: 051J8604
EFIS: 0518000081
DIST-CO-RTE-PM05-SLO-101-7.8/16.5
Award Date02/12/2025
Closeout DateNot set
Work DescriptionCOLD PLANE AC PAVEMENT, RHMA-G, DRAINAGE SYSTEMS AND BARRIERS.
Location DescriptionSAN LUIS OBISPO COUNTY IN AND NEAR ARROYO GRANDE AND PISMO BEACH FROM LOS BERROS ROAD UNDERCROSSING TO PISMO CREEK BRIDGE
QA Service Level1 (Verified on 09/09/2024)

Sample Information

Sample Taken Date07/01/2025 Sample Unique Key61
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/01/2025
Sample typeQuality Assurance A brief description of the sampleRecycled CL2AB
The quantity of what the sample constitutesOne day of placement/ 500 cubic yards From where was the sample collectedJob Site
First name of sampler or witnessed byIsaac Last name of sampler or witnessed byGleffe
Title of samplerTET Telephone number of sampler8053191237
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameSierra Pacific Materials - Templeton Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)N/A
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedStockpile
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size3/4 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2025-07-01-61
DIME Test ID: 2025-07-01-61-2
Testing Lab: CT D05 - Santa Maria Field Laboratory
Test Method: CTM 217-June 2011: Method of Test for Sand Equivalent
Test Release Date: 2025-08-07

Test Results


Number of tests: 1
Input Type: Calculated
Tester's full name: Reyli Angeles
Date of test: 07/01/2025
Temperature correction: 0
Temperature of solution: 72
Clay reading (test 1): 7.3
Sand reading (test 1): 3.4
Sand equivalent (test 1): 47
Sand equivalent before temperature correction: 47
Sand equivalent after temperature correction: 47
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 8/7/2025