Summary for Test 2025-07-01-61-1

Test performed: CTM 202-November 2011

Project Information

Project IdentifiersProject ID: 1000569
DEA: 051J8604
EFIS: 0518000081
DIST-CO-RTE-PM05-SLO-101-7.8/16.5
Award Date02/12/2025
Closeout DateNot set
Work DescriptionCOLD PLANE AC PAVEMENT, RHMA-G, DRAINAGE SYSTEMS AND BARRIERS.
Location DescriptionSAN LUIS OBISPO COUNTY IN AND NEAR ARROYO GRANDE AND PISMO BEACH FROM LOS BERROS ROAD UNDERCROSSING TO PISMO CREEK BRIDGE
QA Service Level1 (Verified on 09/09/2024)

Sample Information

Sample Taken Date07/01/2025 Sample Unique Key61
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/01/2025
Sample typeQuality Assurance A brief description of the sampleRecycled CL2AB
The quantity of what the sample constitutesOne day of placement/ 500 cubic yards From where was the sample collectedJob Site
First name of sampler or witnessed byIsaac Last name of sampler or witnessed byGleffe
Title of samplerTET Telephone number of sampler8053191237
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameSierra Pacific Materials - Templeton Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)N/A
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedStockpile
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size3/4 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2025-07-01-61
DIME Test ID: 2025-07-01-61-1
Testing Lab: CT D05 - Santa Maria Field Laboratory
Test Method: CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2025-08-05

Test Results


What size aggregate is being tested?: 1 in. x No. 4 - Coarse Aggregate
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
For Combined Gradation only, has the fine aggregate sample been reduced?: Yes
For Combined Gradation only, use #40 Sieve?: No
Input Type: Calculated
Tester's full name: Isaac Gleffe
Date of test: 07/01/2025
Sieve SizeCumulative Percent Passing
100 %
100 %
99 %
88 %
79 %
58 %
100 %
General comments (publicly viewable) (Max 1000 characters): fines reduced from passing the #4 sieve 58%

Test was verified on 8/5/2025