Summary for Test 2025-07-25-20-8
Test performed: AASHTO T304-11Project Information
| Project Identifiers | Project ID: 1001312 DEA: 11432844 EFIS: 1125000219 |
|---|---|
| DIST-CO-RTE-PM | 11--- |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Not set |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 07/25/2025 | Sample Unique Key | 20 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/28/2025 |
| Sample type | Acceptance | A brief description of the sample | 10K Milestone |
| The quantity of what the sample constitutes | 3 bags | From where was the sample collected | Supplier |
| First name of sampler or witnessed by | Gerardo | Last name of sampler or witnessed by | Cordero |
| Title of sampler | TET | Telephone number of sampler | 6199366795 |
| Laboratory sample identification | 25-07-25-20-MS | Linked DIME Sample ID | 2025-07-25-19 |
| The fabricator/manufacturer/facility name | Vulcan Otay | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | Not Provided |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
| The plant number | A detailed description of where the material sample was collected | Plant | |
| Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 1-1/2 inch | |
| The concrete mix design number | Lot number | ||
| Sublot number | Aggregate Mix Number | 820801 Otay Val |
Test Details
DIME Sample ID: 2025-07-25-20
DIME Test ID: 2025-07-25-20-8
Testing Lab: CT D11 - District 11 Materials Laboratory
Test Method: AASHTO T304-11: Standard Method of Test for Uncompacted Void Content of Fine Aggregate (Fine of Crushed Particles)
Test Release Date: 2025-08-01
Test Results
What test method is performed?: Method A
Input Type: Measured
Tester's full name: Mohammad Abbassi
Date of test: 07/31/2025
Mass of measure: 190.0 grams
Bulk dry specific gravity: 2.626
Mass of sample and measure #1: 333.2 grams
Mass of sample and measure #2: 333.6 grams
Volume of cylinder: 100.0 mL
Mass of sample #1: 143.2 grams
Mass of sample #2: 143.6 grams
Uncompacted voids #1: 45.5 %
Uncompacted voids #2: 45.3 %
Average uncompacted voids: 45.4 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 8/1/2025 ✔