Summary for Test 2017-11-08-2-16
Test performed: CTM 670-December 2013Project Information
| Project Identifiers | Project ID: 88888 DEA: SMTL-STOCK EFIS: SMTL-STOCK |
|---|---|
| DIST-CO-RTE-PM | 59--- |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Special project for SMTL stock material. Object Code: 1025. J2 DEA: 912680. |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 11/08/2017 | Sample Unique Key | 2 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 11/09/2017 | Sample type | Recertification |
| A brief description of the sample | Flash Welded Rebar Hoops | The quantity of what the sample constitutes | 20 |
| From where was the sample collected | Fabricator | First name of sampler or witnessed by | Jeff |
| Last name of sampler or witnessed by | Smith | Title of sampler | Unknown |
| Telephone number of sampler | Unknown | Laboratory sample identification | Unknown |
| Linked DIME Sample ID | Unknown | The fabricator/manufacturer/facility name | Mission City Rebar |
| Transportation Laboratory (TL) Number | C710496 | Inspector Lot Number from the Transportation Laboratory (TL) Form | B738917 |
| Structure unique identifier | Not set | Structure name | Not set |
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Welded Hoops | Production or Authorization Testing | Authorization Testing |
|---|---|---|---|
| Service or Ultimate | Ultimate | Rebar Heat Number(s) | 158717, 159817 |
| Hoop Manufacturer Lot Number(s) | 1, 1 | Material Standard Code | ASTM A706 |
| Material Grade | 60 | Rebar Size | #5, 6 |
| Diameter of Hoop | 2'-0" | Epoxy Coated | No |
| Epoxy Coating Color | NA | Rebar Manufacturer | Cascade |
| Welding Company | Mission City Rebar | Coating Standards | Uncoated |
| Weld Type | Flash Welded |
Test Details
DIME Sample ID: 2017-11-08-2
DIME Test ID: 2017-11-08-2-16
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical)
Test Release Date: 2017-12-11
Test Results
Number of Samples Tested: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 11/13/2017
UTM: 400KIP
Temperature: 72 F
| Num | Sample | Number of Cycles | Size | Mfg. Lot Number(s) | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|---|
| 1 | Cycle-8 | 100 | #6/19mm | #18801 | 0.44 | 38780 | 88136 | Broke At Wled No Necking | Fred |
General comments (publicly viewable) (Max 1000 characters): Broke At Wled No Necking
Test Graph
Source: Partner Data Point FileTest was verified on 12/4/2017 ✔