Summary for Test 2025-05-15-50-1

Test performed: ASTM C39-17a

Project Information

Project IdentifiersProject ID: 215677
DEA: 044G0804
EFIS: 0412000332
COOP: 042676
DIST-CO-RTE-PM04-SOL-80-R10.4/30.2
Award Date01/18/2022
Closeout DateNot set
Work DescriptionHighway widening, overhead signs, and electronic toll system.
Location DescriptionIn Solano County in Fairfield and Vacaville from 1.0 mile west of Red Top Road Undercrossing to 0.4 mile east of Leisure Town Road Overcrossing.
QA Service Level1 (Verified on 04/11/2022)

Sample Information

Sample Taken Date05/15/2025 Sample Unique Key50
Date that the sample was received by the laboratory/organization performing the testing05/22/2025 Sample typeQuality Assurance
A brief description of the sampleCement type II/V. The quantity of what the sample constitutes3
From where was the sample collectedJob Site First name of sampler or witnessed byAxel
Last name of sampler or witnessed byMetzler Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameCemex
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure nameDavis St- Bent 2 footing, Pile cap top mat overlay
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberCemex 1615759
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected31612308
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedBack of Truck Load 1 Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2025-05-15-50
DIME Test ID: 2025-05-15-50-1
Testing Lab: CT HQ - Vallejo Field Laboratory
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2025-07-31

Test Results


Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Measured
Tester's full name: Mario Periera Vaz
Date of test: 07/31/2025
Capped in accordance with?: ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1: 4.00 in
Average diameter of cylinder 2: 4.00 in
Average diameter of cylinder 3: 4.00 in
Maximum load on cylinder 1: 50829 lb
Maximum load on cylinder 2: 65845 lb
Maximum load on cylinder 3: 70809 lb
Type of fracture pattern of cylinder 1: 5
Type of fracture pattern of cylinder 2: 2
Type of fracture pattern of cylinder 3: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Correction factor for cylinder 3: 1.00
Age of specimen: 77 days
Age of specimen in hours: no data
Cross sectional area of cylinder 1: 12.57 in^2
Cross sectional area of cylinder 2: 12.57 in^2
Cross sectional area of cylinder 3: 12.57 in^2
Compressive strength of cylinder 1: 4043.7 psi
Compressive strength of cylinder 2: 5238.3 psi
Compressive strength of cylinder 3: 5633.2 psi
Compressive strength (to nearest 10 psi): 4970 psi
General comments (publicly viewable) (Max 1000 characters): Vallejo Lab received on 07/16/2025

Test was verified on 7/31/2025 ✔