Summary for Test 2025-07-15-94-7

Test performed: AASHTO T316-22

Project Information

Project IdentifiersProject ID: 1000898
DEA: 010N8304
EFIS: 0124000116
DIST-CO-RTE-PM01-HUM-96-4.9/R13.3
Award Date04/03/2025
Closeout Date11/03/2025
Work DescriptionPLACE RUBBER CHIP SEAL, MICRO-SURFACING, AND REPLACE AC SURFACING.
Location DescriptionHUMBOLDT COUNTY AT HOOPA FROM 4.6 MILES EAST OF WILLOW CREEK BRIDGE TO HOSTLER CREEK BRIDGE
QA Service Level1 (Verified on 03/21/2025)

Sample Information

Sample Taken Date07/15/2025 Sample Unique Key94
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/17/2025
Sample typeQuality Assurance A brief description of the samplePG 64-16
The quantity of what the sample constitutes1 quart can From where was the sample collectedSource
First name of sampler or witnessed bynolan Last name of sampler or witnessed bym
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility namevalero Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form00000 Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeAsphalt Binder Performance GradePG 64-16
ModifiedNo Lot number
Sublot number Tank number
Time of sample HMA Supplier
Certified Asphalt SupplierValero Marketing & Supply - Benicia CA MultigradeNo
Multigrade Type Asphalt Binder Mix Number

Test Details

DIME Sample ID: 2025-07-15-94
DIME Test ID: 2025-07-15-94-7
Testing Lab: Atlas - Denver
Test Method: AASHTO T316-22: Standard Method of Test for Viscosity Determination of Asphalt Binder Using Rotational Viscometer
Test Release Date: 2025-07-31

Test Results


Is viscosity reading in cP/Pa-s?: cP
Input Type: Measured
Tester's full name: Atlas
Date of test: 07/28/2025
Time of test: 00:00 HH:MM
Test Temperature: 135.0 C
Speed: 20 rpm
Spindle size: .463 in
Torque: 14.6 %
Viscosity reading #1 (A) : 365 cP
Viscosity reading #2 (B) : 365 cP
Viscosity reading #3 (C): 365 cP
Average viscosity : 0.365 Pa-s
General comments (publicly viewable) (Max 1000 characters): VISCOCITY

Test was verified on 7/31/2025