Summary for Test 2025-07-22-4-1

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 995193
DEA: 07356604
EFIS: 0719000026
DIST-CO-RTE-PM07-LA-605-R10.2/20.2
Award Date04/04/2024
Closeout DateNot set
Work DescriptionLANE & SLAB REPLACEMENT, COLD PLANE & HMA OVERLAY.
Location DescriptionLOS ANGELES COUNTY IN SANTA FE SPRINGS, PICO RIVERA, WHITTIER, CITY OF INDUSTRY AND EL MONTE FROM TELEGRAPH ROAD UNDERCROSSING TO ROUTE 605/10 SEPARATION
QA Service Level1 (Verified on 10/03/2023)

Sample Information

Sample Taken Date07/22/2025 Sample Unique Key4
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing07/25/2025
Sample typeQuality Assurance A brief description of the sampleA706 GR.60 #6 x 4'-8"x 5'-5" Oval Hoops
The quantity of what the sample constitutes110 hoops From where was the sample collectedFabricator
First name of sampler or witnessed byAlexis Last name of sampler or witnessed byMillan
Title of samplerQA Telephone number of sampler(909)756-9960
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameTNT Rebar Company Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormL191-005-25 Structure unique identifier07-356604
Structure nameLANE & SLAB REPLACEMENT, COLD PLANE & HMA OVERLAY Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingProduction Testing
Service or UltimateUltimate Rebar Heat Number(s)219925, 1202068856
Hoop Manufacturer Lot Number(s)1 Material Standard CodeASTM A706
Material Grade60 Rebar Size#6
Diameter of Hoop4'-8" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerCascade, Nucor
Welding CompanyTNT Rebar Company Coating StandardsUncoated
Weld TypeFlash Welded

Test Details

DIME Sample ID: 2025-07-22-4
DIME Test ID: 2025-07-22-4-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2025-07-31

Test Results


Number of Samples: 4
Input Type: Measured
Tester's full name: Steven Paine
Date of test: 07/31/2025
UTM: NA
Temperature: 0 f
NumSampleMfg. Lot Number(s)SizeArea (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
11160.443873088000ok neckingKleinfelder
22160.443991090500ok neckingKleinfelder
33160.444077092500ok neckingKleinfelder
44160.444020091500ok neckingKleinfelder

General comments (publicly viewable) (Max 1000 characters):

Test was verified on 7/31/2025