Summary for Test 2025-07-22-4-1
Test performed: CTM 670-December 2013Project Information
| Project Identifiers | Project ID: 995193 DEA: 07356604 EFIS: 0719000026 |
|---|---|
| DIST-CO-RTE-PM | 07-LA-605-R10.2/20.2 |
| Award Date | 04/04/2024 |
| Closeout Date | Not set |
| Work Description | LANE & SLAB REPLACEMENT, COLD PLANE & HMA OVERLAY. |
| Location Description | LOS ANGELES COUNTY IN SANTA FE SPRINGS, PICO RIVERA, WHITTIER, CITY OF INDUSTRY AND EL MONTE FROM TELEGRAPH ROAD UNDERCROSSING TO ROUTE 605/10 SEPARATION |
| QA Service Level | 1 (Verified on 10/03/2023) |
Sample Information
| Sample Taken Date | 07/22/2025 | Sample Unique Key | 4 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 07/25/2025 | Sample type | Quality Assurance |
| A brief description of the sample | A706 GR.60 #6 x 4'-8"x 5'-5" Oval Hoops | The quantity of what the sample constitutes | 110 hoops |
| From where was the sample collected | Fabricator | First name of sampler or witnessed by | Alexis |
| Last name of sampler or witnessed by | Millan | Title of sampler | QA |
| Telephone number of sampler | (909)756-9960 | Laboratory sample identification | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | TNT Rebar Company | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | L191-005-25 | |
| Structure unique identifier | 07-356604 | Structure name | LANE & SLAB REPLACEMENT, COLD PLANE & HMA OVERLAY |
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Welded Hoops | Production or Authorization Testing | Production Testing |
|---|---|---|---|
| Service or Ultimate | Ultimate | Rebar Heat Number(s) | 219925, 1202068856 |
| Hoop Manufacturer Lot Number(s) | 1 | Material Standard Code | ASTM A706 |
| Material Grade | 60 | Rebar Size | #6 |
| Diameter of Hoop | 4'-8" | Epoxy Coated | No |
| Epoxy Coating Color | NA | Rebar Manufacturer | Cascade, Nucor |
| Welding Company | TNT Rebar Company | Coating Standards | Uncoated |
| Weld Type | Flash Welded |
Test Details
DIME Sample ID: 2025-07-22-4
DIME Test ID: 2025-07-22-4-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2025-07-31
Test Results
Number of Samples: 4
Input Type: Measured
Tester's full name: Steven Paine
Date of test: 07/31/2025
UTM: NA
Temperature: 0 f
| Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|
| 1 | 1 | 1 | 6 | 0.44 | 38730 | 88000 | ok necking | Kleinfelder |
| 2 | 2 | 1 | 6 | 0.44 | 39910 | 90500 | ok necking | Kleinfelder |
| 3 | 3 | 1 | 6 | 0.44 | 40770 | 92500 | ok necking | Kleinfelder |
| 4 | 4 | 1 | 6 | 0.44 | 40200 | 91500 | ok necking | Kleinfelder |
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 7/31/2025 ✔