Summary for Test 2025-07-22-15-3
Test performed: CTM 342-August 2012Project Information
| Project Identifiers | Project ID: 1000885 DEA: 051R2904 EFIS: 0523000262 |
|---|---|
| DIST-CO-RTE-PM | 05-SB-101,217-Var |
| Award Date | 04/02/2025 |
| Closeout Date | Not set |
| Work Description | BRIDGE DECK REPAIRS, POLYSTER CONCRETE OVERLAYS, AND HMA (TYPE A). |
| Location Description | SANTA BARBARA COUNTY AT VARIOUS LOCATIONS. |
| QA Service Level | 1 (Verified on 01/13/2025) |
Sample Information
| Sample Taken Date | 07/22/2025 | Sample Unique Key | 15 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 07/22/2025 |
| Sample type | Acceptance | A brief description of the sample | Skid Testing Request |
| The quantity of what the sample constitutes | Multiple Lanes | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Jose Fabian | Last name of sampler or witnessed by | Velasco Diaz |
| Title of sampler | Structure Representative | Telephone number of sampler | 6198643162 |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Truesdell Corp. | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | 51-0338 | |
| Structure name | Union Valley Parkway OC | Bid Item | Not set |
Material Information
| Material Type | Roadway/Bridge Surface | Pavement Surface Type | Polyester Concrete |
|---|---|---|---|
| Type of Traffic Control Provided | Stationary Lane Closure | DIST-CO-RTE | 05-SB-101 |
| Direction of Travel | West | Post Mile | 83.45 |
| Lanes to be Tested | Lane #1,Lane #2 | Station |
Test Details
DIME Sample ID: 2025-07-22-15
DIME Test ID: 2025-07-22-15-3
Testing Lab: CT HQ - FFS - Skid Testing
Test Method: CTM 342-August 2012: Method of Test for Surface Skid Resistance with the California Portable Skid Tester (Skid)
Test Release Date: 2025-07-31
Test Results
Pavement or Bridge Deck?: Bridge Deck
Input Type: Measured
Tester's full name: Jessie Wilson
Date of test: 07/29/2025
Air Temperature: 60 F
Tire Pressure: 26 psi
Equipment PST #: 1009
Is Calibration within ± values: Yes
Weather: Clear
Direction/Lane #: EB: Eastbound Direction of Travel
Edge used to measure reference distance: End of Bridge
Edge used to measure position: Right of the Left Center Lane Line
Reference Distance 1: 38 ft
Reference Distance 2: 35 ft
Reference Distance 3: 32 ft
Direction and Lane # for Stationing 1: no data
Direction and Lane # for Stationing 2: no data
Direction and Lane # for Stationing 3: no data
Position for Stationing 1: 8 ft
Position for Stationing 2: 8 ft
Position for Stationing 3: 8 ft
Percent Grade for 1st Stationing: 2.0 %
Percent Grade for 2nd Stationing: 2.0 %
Percent Grade for 3rd Stationing: 2.0 %
Corrected Coefficients of Friction for Stationing 1: 0.41
Corrected Coefficients of Friction for Stationing 2: 0.41
Corrected Coefficients of Friction for Stationing 3: 0.41
Average Coefficient of Friction: 0.41
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 7/31/2025 ✔