Summary for Test 2025-04-17-99-2

Test performed: CTM 521-June 2020

Project Information

Project IdentifiersProject ID: 214698
DEA: 120N8904
EFIS: 1214000130
DIST-CO-RTE-PM12-ORA-133-8.3/M9.3
Award Date11/09/2023
Closeout DateNot set
Work DescriptionCONSTRUCT AUXILIARY LANE.
Location DescriptionORANGE COUNTY IN IRVINE FROM ROUTE 133/405 SEPARATION TO IRVINE CENTER DRIVE OVERCROSSING
QA Service Level1 (Verified on 02/22/2021)

Sample Information

Sample Taken Date04/17/2025 Sample Unique Key99
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/18/2025
Sample typeQuality Control A brief description of the sample4x8 Cylinders
The quantity of what the sample constitutes9 From where was the sample collectedJob Site
First name of sampler or witnessed byRyan Last name of sampler or witnessed byMilum
Title of samplerQC Field Technician Telephone number of sampler
Laboratory sample identificationSet 1 Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameJob Site Transportation Laboratory (TL) NumberUnknown
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifier00-0000
Structure name Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberS63C453T13
The truck number from where the sample was collectedLoad 1 The batch plant ticket number from where the sample was collected0
Concrete batch plantUnknown The fabricator/manufacturer designation for the sampleSet 1
A detailed description of where the material sample was collectedBarrier Transitions RW #61, 67, and 77 Where the material sample would have been placed if not sampledUnknown
From Lot No.1 Bag Lot No.1

Test Details

DIME Sample ID: 2025-04-17-99
DIME Test ID: 2025-04-17-99-2
Testing Lab: G3 Quality, Incorporated - Cerritos
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2025-10-17

Test Results


Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Calculated
Tester's full name: Isac Vasquez
Date of test: 05/15/2025
Capped in accordance with?: ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1: 4.00 in
Average diameter of cylinder 2: 4.00 in
Average diameter of cylinder 3: 4.00 in
Maximum load on cylinder 1: 73384 lb
Maximum load on cylinder 2: 74160 lb
Maximum load on cylinder 3: 76775 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 2
Type of fracture pattern of cylinder 3: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Correction factor for cylinder 3: 1.00
Age of specimen: 28 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 12.57 in^2
Cross sectional area of cylinder 2: 12.57 in^2
Cross sectional area of cylinder 3: 12.57 in^2
Compressive strength (to nearest 10 psi): 5950 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 10/17/2025