Summary for Test 2025-06-09-112-2
Test performed: AASHTO T308-10Project Information
| Project Identifiers | Project ID: 995129 DEA: 07346204 EFIS: 0718000072 |
|---|---|
| DIST-CO-RTE-PM | 07-LA,VEN-2,23,101-Var |
| Award Date | 04/10/2024 |
| Closeout Date | Not set |
| Work Description | UPGRADE AND INSTALL NEW TRANSPORTATION MANAGEMENT SYSTEM ELEMENTS. |
| Location Description | LOS ANGELES AND VENTURA COUNTIES AT VARIOUS LOCATIONS |
| QA Service Level | 1 (Verified on 11/08/2024) |
Sample Information
| Sample Taken Date | 06/09/2025 | Sample Unique Key | 112 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/11/2025 |
| Sample type | Acceptance | A brief description of the sample | 3/4" HMA-A |
| The quantity of what the sample constitutes | 750 Tons | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | Chris | Last name of sampler or witnessed by | Hurtado |
| Title of sampler | Vulcan QC | Telephone number of sampler | |
| Laboratory sample identification | 25-279 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | Vulcan Materials Sun Valley | Transportation Laboratory (TL) Number | 019841 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | |
| Sublot number | HMA Mix Number | 220200W SVA VLO | |
| Binder content (%) | 4.7 | Virgin binder PG | |
| Design binder PG | Binder Supplier | Valero | |
| RAP content (%) | Not set | WMA Additives | |
| Antistrip type |
Test Details
DIME Sample ID: 2025-06-09-112
DIME Test ID: 2025-06-09-112-2
Testing Lab: CT D07 - Materials Field Laboratory, Unit 1953
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2025-07-29
Test Results
What temperature unit is used?: Celsius
Input Type: Measured
Tester's full name: Daniel Gomez
Date of test: 06/19/2025
Test procedure used?: Method A
Mass of the specimen basket assembly: 4056.7 g
Mass of the specimen and specimen basket assembly prior to ignition: 6144.5 g
Mass of HMA Sample prior to ignition: 2087.8 g
Mass Loss: 111.5 g
Mass of aggregate remaining after ignition: 1976.3 g
Correction Factor (Percent by mass of HMA Specimen): 0.27 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.00 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 5.07 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 7/29/2025 ✔