Summary for Test 2025-07-01-52-1

Test performed: AASHTO T209-22

Project Information

Project IdentifiersProject ID: 994966
DEA: 073255U4
EFIS: 0722000129
DIST-CO-RTE-PM07-LA-605-20.2/26
Award Date04/12/2023
Closeout DateNot set
Work DescriptionINDIVIDUAL SLAB REPLACEMENT, COLD PLANE AC
Location DescriptionLOS ANGELES COUNTY IN BALDWIN PARK AND IRWINDALE FROM ROUTE 10/605 SEPARATION TO 0.2 MILE NORTH OF ROUTE 210/605 SEPARATION
QA Service Level1 (Verified on 07/13/2023)

Sample Information

Sample Taken Date07/01/2025 Sample Unique Key52
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/03/2025
Sample typeAcceptance A brief description of the sample3/4" RHMA-G
The quantity of what the sample constitutes750 Tons From where was the sample collectedManufacturer
First name of sampler or witnessed byKleinfelder Last name of sampler or witnessed byNA
Title of sampler Kleinfelder QA Technician Telephone number of sampler
Laboratory sample identification25-438 Linked DIME Sample ID
The fabricator/manufacturer/facility nameAAA Irwindale Transportation Laboratory (TL) Number003498
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeRHMA-G
HMA Grading3/4 inch Lot number
Sublot number HMA Mix Number106835
Binder content (%)7.5 Virgin binder PG
Design binder PG Binder SupplierSan Juaquin Refinery
RAP content (%)Not set WMA Additives
Antistrip type

Test Details

DIME Sample ID: 2025-07-01-52
DIME Test ID: 2025-07-01-52-1
Testing Lab: CT D07 - Materials Field Laboratory, Unit 1953
Test Method: AASHTO T209-22: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2025-07-28

Test Results


Number of Samples: 1
What is the unit of measurement for theoretical density?: US Units
Mass Determination: Air
Input Type: Measured
Tester's full name: James Lee
Date of test: 07/25/2025
Method Performed: Mechanical Agitation - Method A
Mass of container filled with water 1: 7353.3 grams
Mass of oven-dry sample in air for Sample 1: 2550.8 grams
Mass of container filled with the sample and water for Sample 1: 8858.9 grams
Temperature of Water: 77 °F
Specific Gravity for Sample 1: 2.440
Theoretical maximum density at 25°C (77°F): 151.9 lb/ft^3
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 7/28/2025