Summary for Test 2025-07-01-49-1

Test performed: AASHTO T209-22

Project Information

Project IdentifiersProject ID: 995085
DEA: 07322904
EFIS: 0716000059
DIST-CO-RTE-PM07-LA-27-0.0/18.6
Award Date11/06/2023
Closeout DateNot set
Work DescriptionREMOVE EXISTING AC PAVEMENT & HMA OVERLAY.
Location DescriptionLOS ANGELES COUNTY IN AND NEAR LOS ANGELES FROM ROUTE 1 TO DEVONSHIRE STREET
QA Service Level1 (Verified on 09/11/2023)

Sample Information

Sample Taken Date07/01/2025 Sample Unique Key49
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/03/2025
Sample typeAcceptance A brief description of the sample1/2" RHMA-G
The quantity of what the sample constitutes750 Tons From where was the sample collectedManufacturer
First name of sampler or witnessed byArnold Last name of sampler or witnessed byTruong
Title of samplerMREA Telephone number of sampler
Laboratory sample identification25-432 Linked DIME Sample ID
The fabricator/manufacturer/facility nameVulcan Materials Sun Valley Transportation Laboratory (TL) NumberA701258
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeRHMA-G
HMA Grading1/2 inch Lot number
Sublot number HMA Mix Number326120M SVA VLO
Binder content (%)7.5 Virgin binder PG
Design binder PG Binder SupplierValero
RAP content (%)Not set WMA Additives
Antistrip type

Test Details

DIME Sample ID: 2025-07-01-49
DIME Test ID: 2025-07-01-49-1
Testing Lab: CT D07 - Materials Field Laboratory, Unit 1953
Test Method: AASHTO T209-22: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2025-07-28

Test Results


Number of Samples: 1
What is the unit of measurement for theoretical density?: US Units
Mass Determination: Air
Input Type: Measured
Tester's full name: Chad Chotibhongs
Date of test: 07/24/2025
Method Performed: Mechanical Agitation - Method A
Mass of container filled with water 1: 7353.3 grams
Mass of oven-dry sample in air for Sample 1: 1571.8 grams
Mass of container filled with the sample and water for Sample 1: 8279.3 grams
Temperature of Water: 77 °F
Specific Gravity for Sample 1: 2.434
Theoretical maximum density at 25°C (77°F): 151.5 lb/ft^3
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 7/28/2025