Summary for Test 2025-07-18-6-1

Test performed: CTM 521-June 2020

Project Information

Project IdentifiersProject ID: 1000279
DEA: 023H70U4
EFIS: 0223000161
DIST-CO-RTE-PM02-TRI-299-15.0/25.7
Award Date08/09/2024
Closeout DateNot set
Work DescriptionRHMA-G, HMA (TYPE A), COLD PLANE AC, & SOLDIER PILE RETAINING WALL.
Location DescriptionTRINITY COUNTY NEAR DEL LOMA FROM 1.0 MILE EAST OF TRINITY RIVER BRIDGE NO.05-0006 TO 0.1 MILE WEST OF PRAIRIE CREEK ROAD
QA Service Level1 (Verified on 04/30/2024)

Sample Information

Sample Taken Date07/18/2025 Sample Unique Key6
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/19/2025
Sample typeQuality Assurance A brief description of the sample6 4x8 concrete cylinders
The quantity of what the sample constitutes1 CU/FT From where was the sample collectedJob Site
First name of sampler or witnessed byAndrew Last name of sampler or witnessed byGrinsell
Title of samplerASR Telephone number of sampler707-498-4009
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameJF Shea Construction, Shasta Redi-Mix, Redding, CA Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberMFSCL1675.45
The truck number from where the sample was collected The batch plant ticket number from where the sample was collectedpending
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedBack of Truck Where the material sample would have been placed if not sampledBarrier Transition Blocks
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2025-07-18-6
DIME Test ID: 2025-07-18-6-1
Testing Lab: CT D01 - District 1 Materials Laboratory
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2025-07-25

Test Results


Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Calculated
Tester's full name: Tom Brown
Date of test: 07/25/2025
Capped in accordance with?: ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1: 4.00 in
Average diameter of cylinder 2: 4.00 in
Average diameter of cylinder 3: 4.00 in
Maximum load on cylinder 1: 57896 lb
Maximum load on cylinder 2: 60055 lb
Maximum load on cylinder 3: 62407 lb
Type of fracture pattern of cylinder 1: 5
Type of fracture pattern of cylinder 2: 3
Type of fracture pattern of cylinder 3: 5
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Correction factor for cylinder 3: 1.00
Age of specimen: 7 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 12.57 in^2
Cross sectional area of cylinder 2: 12.57 in^2
Cross sectional area of cylinder 3: 12.57 in^2
Compressive strength (to nearest 10 psi): 4780 psi
General comments (publicly viewable) (Max 1000 characters): 7/25/25 7 day break

Test was verified on 7/25/2025