Summary for Test 2025-07-10-3-8
Test performed: ASTM F606-21Project Information
| Project Identifiers | Project ID: 994358 DEA: 033J3304 EFIS: 0322000251 |
|---|---|
| DIST-CO-RTE-PM | 03-SAC-12-0/0.5 |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | MMBN Project. Replace backup drive system, replace lift span deck, install hydraulic barrier system and new generator, replace electrical control system, install new traffic gates and elevators, traffic control, |
| Location Description | Not set |
| QA Service Level | 1 (Verified on 10/25/2022) |
Sample Information
| Sample Taken Date | 07/10/2025 | Sample Unique Key | 3 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/10/2025 |
| Sample type | Quality Assurance | A brief description of the sample | A325 Fasteners (Galvanized) |
| The quantity of what the sample constitutes | 26 | From where was the sample collected | Distributor |
| First name of sampler or witnessed by | Edward | Last name of sampler or witnessed by | Leach |
| Title of sampler | Telephone number of sampler | 7072903887 | |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Bay Bolt Oakland, Ca | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
|---|---|---|---|
| Heat Number(s) | 100786789 8000034334 32028550 | Nut Mfg. Lot Number(s) | W000237418 |
| Washer Mfg. Lot Number(s) | 176212 | Bolt Specification | A325 |
| Bolt Length(s) | 4.25" | Nut Specification | A563 |
| Washer Specification | F436 | Finish | HDG |
| Diameter/Size | 7/8" | Bolt Mfg. Lot Number | 392877A |
| Rocap Test Requirement(s) | Lubricant Requirements(s) | ||
| Washer Inner Diameter(s) |
Test Details
DIME Sample ID: 2025-07-10-3
DIME Test ID: 2025-07-10-3-8
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2025-07-25
Test Results
Number of Bolt Samples: 1
Input Type: Measured
Tester's full name: Steven Paine
Date of test: 07/25/2025
UTM: NA
Temperature: 0 f
| Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Wedge Angle (deg) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|
| 1 | 1A | 392877A | .875 | 67200 | 0000 | 0000 | A325 | Atlas |
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 7/25/2025 ✔