Summary for Test 2025-06-26-50-5

Test performed: AASHTO T240-23

Project Information

Project IdentifiersProject ID: 1000117
DEA: 020J0104
EFIS: 0219000044
DIST-CO-RTE-PM02-TEH-99-4.2/4.8
Award Date07/11/2024
Closeout DateNot set
Work DescriptionPLACE HMA, CCTV TOWER AND INSTALL LIGHTING SYSTEM.
Location DescriptionTEHAMA COUNTY ABOUT 7.0 MILES SOUTH OF LOS MOLINOS FROM 0.3 MILE SOUTH OF SOUTH AVENUE TO 0.6 MILE SOUTH OF VINA ROAD
QA Service Level1 (Verified on 03/18/2024)

Sample Information

Sample Taken Date06/26/2025 Sample Unique Key50
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/01/2025
Sample typeQuality Assurance A brief description of the samplePG 70-10
The quantity of what the sample constitutes2 cans From where was the sample collectedSource
First name of sampler or witnessed byBrandon Last name of sampler or witnessed byWhite
Title of samplerTET Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility namePacific Northwest Transportation Laboratory (TL) Number858139
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeAsphalt Binder Performance GradePG 70-10
Modified Lot number1
Sublot number1 Tank number
Time of sample HMA Supplier
Certified Asphalt SupplierPacific Northwest Oil - Stockton CA MultigradeNo
Multigrade Type Asphalt Binder Mix Number

Test Details

DIME Sample ID: 2025-06-26-50
DIME Test ID: 2025-06-26-50-5
Testing Lab: Atlas - Denver
Test Method: AASHTO T240-23: Standard Method of Test for Effect of Heat and Air on a Moving Film of Asphalt Binder (Rolling Thin-Film Oven Test)
Test Release Date: 2025-07-25

Test Results


Is mass change based on one or two containers?: Two
Is mass change correction factor needed?: Yes
Input Type: Measured
Tester's full name: Atlas
Date of test: 07/16/2025
Any material loss from containers during heating process/testing?: No
Mass of container #1 before test (m1i): 211.415 grams
Mass of container #2 before test (m2i): 207.800 grams
Mass of container #1 after test (m1f): 211.416 grams
Mass of container #2 after test (m2f): 207.784 grams
Mass of empty container #1: 176.583 grams
Mass of empty container #2: 172.969 grams
Mass correction factor: 0.030
Average mass change: 0.008 percent
General comments (publicly viewable) (Max 1000 characters): Mass Change

Test was verified on 7/25/2025