Summary for Test 2025-07-23-24-1

Test performed: CTM 231-March 2013

Project Information

Project IdentifiersProject ID: 1000301
DEA: 07333704
EFIS: 0716000316
DIST-CO-RTE-PM07-LA-138-43.4/51.4
Award Date07/30/2024
Closeout DateNot set
Work DescriptionCONSTRUCT ADA CURB RAMPS, SIDEWALK, AND DRIVEWAY.
Location DescriptionLOS ANGELES COUNTY IN PALMDALE FROM ROUTE 14 JUNCTION (SOUTH) TO AVENUE T
QA Service Level1 (Verified on 08/12/2024)

Sample Information

Sample Taken Date07/23/2025 Sample Unique Key24
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/23/2025
Sample typeAcceptance A brief description of the sampleAggregate Base
The quantity of what the sample constitutes750sqft From where was the sample collectedJob Site
First name of sampler or witnessed byChad Last name of sampler or witnessed byChotibhongs
Title of samplerMREA Telephone number of sampler2134076963
Laboratory sample identification25-2376 Linked DIME Sample ID
The fabricator/manufacturer/facility nameOn-Site Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeSoil The fabricator's/manufacturer's product name for the sample
The fabricator/manufacturer designation for the sample A detailed description of where the material sample was collectedCTM 231 test locations
Where the material sample would have been placed if not sampled

Test Details

DIME Sample ID: 2025-07-23-24
DIME Test ID: 2025-07-23-24-1
Testing Lab: CT D07 - Materials Field Laboratory, Unit 1953
Test Method: CTM 231-March 2013: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates Using Nuclear Gages
Test Release Date: 2025-07-24

Test Results


Method Type:: Direct Read
Number of Tests:: 3
Common Test Maximum Used:: No
Input Type: Measured
Tester's full name: Chad Chotibhongs
Date of test: 07/24/2025
Gage No.: 31105
Test No.: 1
Nuclear By: Chad Chotibhongs
Non-Bias Plan No.: 9
Depth: 5"
Material No.: On-site
Material Type: Aggregate Base
Impact By: Chad Chotibhongs
Standard Count Density: 2068 g/cc
Count or Density 1: 1.98 g/cc
Count or Density 2: 1.96 g/cc
Count or Density 3: 1.92 g/cc
Standard Count Moisture: 591 g/cc
Moisture Count 1: 0.3 g/cc
Moisture Count 2: 0.3 g/cc
Moisture Count 3: 0.28 g/cc
Sum of Count or Density: 5.86 g/cc
Average of Count or Density: 1.95 g/cc
Sum of Moisture Count: 0.88 g/cc
Average of Moisture Count: 0.29 g/cc
Calculated Percent Relative Compaction: 90.9 %
Reported Percent Relative Compaction: 91 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 7/24/2025