Summary for Test 2025-06-23-34-4

Test performed: AASHTO T51-22

Project Information

Project IdentifiersProject ID: 1000014
DEA: 010H1504
EFIS: 0117000116
DIST-CO-RTE-PM01-MEN-162-R0.0/25.7
Award Date03/26/2024
Closeout DateNot set
Work DescriptionHMA, RHMA, AND GEOSYNTHETIC PAVEMENT INTERLAYER.
Location DescriptionMENDOCINO COUNTY NEAR LONGVALE FROM ROUTE 101 TO 1.1 MILES SOUTH OF POONKINNEY ROAD NEAR COVELO
QA Service Level1 (Verified on 01/10/2024)

Sample Information

Sample Taken Date06/23/2025 Sample Unique Key34
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/27/2025
Sample typeQuality Assurance A brief description of the sample1 can PG 58-22
The quantity of what the sample constitutes1 can binder From where was the sample collectedSource
First name of sampler or witnessed byGranite QC Last name of sampler or witnessed byGranite
Title of samplerPlant QC Telephone number of sampler
Laboratory sample identification25-110 Linked DIME Sample ID
The fabricator/manufacturer/facility nameGranite Ukiah Transportation Laboratory (TL) Number778806
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeAsphalt Binder Performance GradePG 58-22
Modified Lot number1
Sublot number1 Tank number
Time of sample07:41 HMA Supplier
Certified Asphalt SupplierValero Marketing & Supply - Benicia CA MultigradeNo
Multigrade Type Asphalt Binder Mix Number

Test Details

DIME Sample ID: 2025-06-23-34
DIME Test ID: 2025-06-23-34-4
Testing Lab: Atlas - Denver
Test Method: AASHTO T51-22: Standard Method of Test for Ductility of Asphalt Materials (Asphalt Binder)
Test Release Date: 2025-07-25

Test Results


Is a normal test obtainable?: Yes
Number of replicates tested: Three
Input Type: Measured
Tester's full name: Atlas
Date of test: 07/16/2025
Ductility of test #1 (D1): 150 cm
Ductility of test #2 (D2): 150 cm
Ductility of test #3 (D3): 150 cm
Ductility of sample: 150 cm
General comments (publicly viewable) (Max 1000 characters): Ductility

Test was verified on 7/25/2025