Summary for Test 2025-06-17-109-5
Test performed: AASHTO T51-22Project Information
| Project Identifiers | Project ID: 1000636 DEA: 024H03U4 EFIS: 0224000026 |
|---|---|
| DIST-CO-RTE-PM | 02-PLU-89-12.9/20.0,20.6/21.0 |
| Award Date | 12/20/2024 |
| Closeout Date | 02/26/2026 |
| Work Description | HMA OVERLAY. |
| Location Description | PLUMAS COUNTY IN AND NEAR GREENVILLE FROM 0.8 MILE SOUTH OF DIXIE CANYON ROAD TO WOLF CREEK BRIDGE AND FROM MILL STREET TO 0.4 MILE NORTH OF HILLSIDE DRIVE |
| QA Service Level | 1 (Verified on 09/24/2024) |
Sample Information
| Sample Taken Date | 06/17/2025 | Sample Unique Key | 109 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 06/30/2025 | Sample type | Quality Assurance |
| A brief description of the sample | PG 58-22 PSE | The quantity of what the sample constitutes | 2 Cans |
| From where was the sample collected | Source | First name of sampler or witnessed by | Damion |
| Last name of sampler or witnessed by | Farley | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Ward Lake Plant | |
| Transportation Laboratory (TL) Number | 857987 | Inspector Lot Number from the Transportation Laboratory (TL) Form | |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Asphalt Binder | Performance Grade | PG 58-22 |
|---|---|---|---|
| Modified | No | Lot number | |
| Sublot number | Tank number | ||
| Time of sample | HMA Supplier | Ward Lake Plant | |
| Certified Asphalt Supplier | Albina Asphalt (Klamath Falls Plant) - Klamath Falls OR | Multigrade | No |
| Multigrade Type | Asphalt Binder Mix Number | ||
| HMA Type | Not set | HMA Supplier Mix ID Number | Not set |
Test Details
DIME Sample ID: 2025-06-17-109
DIME Test ID: 2025-06-17-109-5
Testing Lab: Atlas - Denver
Test Method: AASHTO T51-22: Standard Method of Test for Ductility of Asphalt Materials (Asphalt Binder)
Test Release Date: 2025-07-25
Test Results
Is a normal test obtainable?: Yes
Number of replicates tested: Three
Input Type: Measured
Tester's full name: Atlas
Date of test: 07/16/2025
Ductility of test #1 (D1): 150 cm
Ductility of test #2 (D2): 150 cm
Ductility of test #3 (D3): 150 cm
Ductility of sample: 150 cm
General comments (publicly viewable) (Max 1000 characters): Ductility
Test was verified on 7/25/2025 ✔