Summary for Test 2025-07-21-12-2

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 1000369
DEA: 09378804
EFIS: 0919000002
DIST-CO-RTE-PM09-MNO-395-R9.8/R12.6
Award Date08/29/2024
Closeout DateNot set
Work DescriptionPLACE HMA AND ASPHALT BASE, RECYCLE PAVEMENT AND MODIFY ELECTRICAL.
Location DescriptionMONO COUNTY NEAR TOM\\\\'S PLACE FROM 0.5 MILE NORTH OF LOWER ROCK CREEK ROAD TO 1.3 MILES SOUTH OF SOUTH LANDING OVERCROSSING
QA Service Level1 (Verified on 09/02/2024)

Sample Information

Sample Taken Date07/21/2025 Sample Unique Key12
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/22/2025
Sample typeAcceptance A brief description of the sample3/4" HMA-A-SP PG58-34M R15
The quantity of what the sample constitutes750 Tons From where was the sample collectedJob Site
First name of sampler or witnessed byJeff Last name of sampler or witnessed byPuente
Title of samplerConsultant Telephone number of sampler
Laboratory sample identificationHMA-46 Linked DIME Sample ID
The fabricator/manufacturer/facility nameGranite 5 Bridges Plant Bishop Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/4 inch Lot number
Sublot number HMA Mix Number
Binder content (%)0.0 Virgin binder PG
Design binder PG Binder Supplier
RAP content (%)Not set WMA Additives
Antistrip type

Test Details

DIME Sample ID: 2025-07-21-12
DIME Test ID: 2025-07-21-12-2
Testing Lab: CT D09 - Bishop Field Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2025-07-23

Test Results


What temperature unit is used?: Celsius
Input Type: Measured
Tester's full name: Derek Carrington
Date of test: 07/23/2025
Test procedure used?: Method A
Mass of the specimen basket assembly: 4276.0 g
Mass of the specimen and specimen basket assembly prior to ignition: 6487.7 g
Mass of HMA Sample prior to ignition: 2211.7 g
Mass Loss: 108.6 g
Mass of aggregate remaining after ignition: 2103.1 g
Correction Factor (Percent by mass of HMA Specimen): 0.28 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.00 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 4.63 %
General comments (publicly viewable) (Max 1000 characters): HMA-46

Test was verified on 7/23/2025