Summary for Test 2025-05-02-65-1

Test performed: ASTM A722-18

Project Information

Project IdentifiersProject ID: 215620
DEA: 01436404
EFIS: 0100000193
DIST-CO-RTE-PM01-DN-101-35.8/36.5
Award Date07/11/2022
Closeout DateNot set
Work DescriptionDr. Fine Bridge Replacement
Location DescriptionDR. FINE BRIDGE REPLACEMENT FROM LAKE EARL DR TO S FRED D. HAIGHT DR ON HWY 101 ACROSS SMITH RIVER.
QA Service Level1 (Verified on 03/26/2021)

Sample Information

Sample Taken Date05/02/2025 Sample Unique Key65
Date that the sample was received by the laboratory/organization performing the testing05/14/2025 Sample typeQuality Assurance
A brief description of the sample3" A722 Threaded Bar The quantity of what the sample constitutes3
From where was the sample collectedManufacturer First name of sampler or witnessed byNA
Last name of sampler or witnessed byNA Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameWilliams Form Eng
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Threaded Bar Production or Authorization TestingProduction Testing
Threaded Bar SpecificationASTM A722 Threaded Bar Grade150
Threaded Bar Type Rebar Size
Nut Specification for Threaded BarA29 System ManufacturerWilliams Form
Epoxy Coating ColorNA Threaded Bar Application
Coating StandardsUncoated Bar Heat Number(s)1000226351
Nut Heat Number(s)X9953 Bar Lot Number
Nut Lot Number75Y2D Coupler Heat Number(s)
Coupler Grade

Test Details

DIME Sample ID: 2025-05-02-65
DIME Test ID: 2025-05-02-65-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A722-18: Standard Specification for High-Strength Steel Bars for Prestressed Concrete (Tensile)
Test Release Date: 2025-07-23

Test Results


Number of Threaded Bar Samples: 3
Input Type: Measured
Tester's full name: Andrew Auvinen
Date of test: 07/23/2025
UTM: NA
Temperature: 72 f
NumSampleSizeMfg LotArea (sqin)Tensile Strength (psi)Stress at Offset (psi)Total Elongation (%)Reduction of area (%)CommentsTested By
113NA6.85012990000NASmith Emery
223NA6.85013020000NASmith Emery
333NA6.85013260000NASmith Emery

General comments (publicly viewable) (Max 1000 characters): Did not pull to break, UTM stopped test at capacity.

Test was verified on 7/23/2025 ✔