Summary for Test 2025-07-14-60-3

Test performed: AASHTO T209-12

Project Information

Project IdentifiersProject ID: 1000279
DEA: 023H70U4
EFIS: 0223000161
DIST-CO-RTE-PM02-TRI-299-15.0/25.7
Award Date08/09/2024
Closeout DateNot set
Work DescriptionRHMA-G, HMA (TYPE A), COLD PLANE AC, & SOLDIER PILE RETAINING WALL.
Location DescriptionTRINITY COUNTY NEAR DEL LOMA FROM 1.0 MILE EAST OF TRINITY RIVER BRIDGE NO.05-0006 TO 0.1 MILE WEST OF PRAIRIE CREEK ROAD
QA Service Level1 (Verified on 04/30/2024)

Sample Information

Sample Taken Date07/14/2025 Sample Unique Key60
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/14/2025
Sample typeProduction Start-Up A brief description of the sample1 bag of Combined RAP
The quantity of what the sample constitutesProduction Start-Up Evaluation From where was the sample collectedManufacturer
First name of sampler or witnessed byCindy Last name of sampler or witnessed byBryant
Title of samplerTET Telephone number of sampler
Laboratory sample identificationD79954B Linked DIME Sample ID
The fabricator/manufacturer/facility nameJ.F. Shea Construction — Fawndale Rock and Asphalt (Redding, CA) Transportation Laboratory (TL) Number858522
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeReclaimed Asphalt Pavement RAP SourceFawndale
Aggregate Size3/8-inch Aggregate Source
RAP Stockpile Stockpile Size (tons)
Reclaimed Asphalt Pavement Mix Number

Test Details

DIME Sample ID: 2025-07-14-60
DIME Test ID: 2025-07-14-60-3
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2025-12-23

Test Results


Number of tests: 1
What is the unit of measurement for theoretical density?: SI Units
Mass Determination: Air
Input Type: Measured
Tester's full name: Josh Ferency
Date of test: 07/18/2025
Method Performed: Mechanical Agitation - Method A
Mass of container filled with water: 7334 grams
Mass of oven-dry sample in air for Sample 1: 1617.1 grams
Mass of container filled with the sample and water for Sample 1: 8323.7 grams
Temperature of Water: 76 °F
Specific Gravity for Sample 1: 2.577
Theoretical maximum density at 25°C (77°F): 2569.5 kg/m^3
General comments (publicly viewable) (Max 1000 characters): Gmmr=2.577

Test was verified on 12/23/2025