Summary for Test 2025-07-09-34-5

Test performed: AASHTO T283-14

Project Information

Project IdentifiersProject ID: 1001213
DEA: 11431644
EFIS: 1122000232
DIST-CO-RTE-PM11-SD-78-N17.7
Award DateNot set
Closeout DateNot set
Work DescriptionCold plane, RHMA overlay, Concrete Barriers, Landscape and Electrical.
Location DescriptionIN SAN DIEGO COUNTY FROM ROUTE 78/5 SEPARATION TO 0.3 MILE EAST OF ESCONDIDO BOULEVARD UNDERCROSSING.
QA Service Level1 (Verified on 05/07/2025)

Sample Information

Sample Taken Date07/09/2025 Sample Unique Key34
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/10/2025
Sample typeQuality Assurance A brief description of the sampleJMFV
The quantity of what the sample constitutes12 boxes From where was the sample collectedSource
First name of sampler or witnessed byGerardo Last name of sampler or witnessed byCordero
Title of samplerTET Telephone number of sampler6199366795
Laboratory sample identification25-07-09-34-JMFV Linked DIME Sample ID2025-07-09-35
The fabricator/manufacturer/facility nameMartin Marietta Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeRHMA-G
HMA Grading1/2 inch Lot number
Sublot number HMA Mix Number21218180
Binder content (%)Not set Virgin binder PGNot set
Design binder PGNot set Binder SupplierNot set
RAP content (%)Not set WMA AdditivesNot set
Antistrip typeNot set

Test Details

DIME Sample ID: 2025-07-09-34
DIME Test ID: 2025-07-09-34-5
Testing Lab: CT D11 - District 11 Materials Laboratory
Test Method: AASHTO T283-14: Standard Method of Test for Resistance of Compacted Asphalt Mixtures to Moisture-Induced Damage (Moisture Content)
Test Release Date: 2025-07-23

Test Results


Unit system used?: SI Units
Input Type: Measured
Tester's full name: Daniel Smith
Date of test: 07/23/2025
Wet 1Wet 2Wet 3Dry 1Dry 2Dry 3
Untreated
150.0 mm150.0 mm150.0 mm150.0 mm150.0 mm150.0 mm
95.0 mm95.0 mm95.0 mm95.0 mm95.0 mm95.0 mm
3646.5 g3645.5 g3646.1 g3644.7 g3644.5 g3645.8 g
2045.8 g2044.0 g2041.3 g2045.1 g2046.2 g2042.5 g
3664.2 g3665.2 g3663.9 g3663.8 g3664.2 g3665.7 g
2.420 2.420 2.420 2.420 2.420 2.420
3724.7 g3726.1 g3726.7 g
2045.8 g2044.0 g2041.3 g
95.1 mm95.1 mm95.1 mm
225 mmHg225 mmHg225 mmHg
0 inHg0 inHg0 inHg
10 minutes10 minutes10 minutes

1618.4 cm^3

1621.2 cm^3

1622.6 cm^3

1618.7 cm^3

1618.0 cm^3

1623.2 cm^3

2.253

2.249

2.247

2.252

2.252

2.246

6.9 %

7.1 %

7.1 %

6.9 %

6.9 %

7.2 %

111.7 cm^3

115.1 cm^3

115.2 cm^3

111.7 cm^3

111.6 cm^3

116.9 cm^3

3724.7 g

3726.1 g

3726.7 g

3735.9 g

3737.6 g

3738.3 g

1678.9 cm^3

1682.1 cm^3

1685.4 cm^3

78.2 cm^3

80.6 cm^3

80.6 cm^3

70 %

70 %

70 %

3.7 %

3.8 %

3.9 %

12562 N

9559 N

11512 N

15787 N

15608 N

14857 N

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

561 kPa

427 kPa

514 kPa

705 kPa

697 kPa

664 kPa

73 psi

100 psi

0.73
General comments (publicly viewable) (Max 1000 characters): Complies WET Target > 70 psi, tested 73 psi and DRY Target > 100 psi, Tested 100 psi

Test was verified on 7/23/2025