Summary for Test 2025-07-07-6-1
Test performed: CTM 670-December 2013Project Information
| Project Identifiers | Project ID: 994574 DEA: 050C7334 EFIS: 0518000116 |
|---|---|
| DIST-CO-RTE-PM | 05-SCR-1-10.5/13.4 |
| Award Date | 06/29/2023 |
| Closeout Date | Not set |
| Work Description | CONSTRUCT OVERCROSSING AND AUXILIARY LANE/ Replace Capitola Ave OC + RWs and SWs |
| Location Description | SANTA CRUZ COUNTY IN AND NEAR CITY OF CAPITOLA FROM STATE PARK DRIVE OVERCROSSING TO 0.2 MILE NORTH OF BAY AVENUE UNDERCROSSING |
| QA Service Level | 1 (Verified on 04/13/2023) |
Sample Information
| Sample Taken Date | 07/07/2025 | Sample Unique Key | 6 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 07/23/2025 |
| Sample type | Quality Assurance | A brief description of the sample | #5 3'-2" Welded Hoops |
| The quantity of what the sample constitutes | 221 | From where was the sample collected | Fabricator |
| First name of sampler or witnessed by | Adrian | Last name of sampler or witnessed by | Sanchez |
| Title of sampler | Telephone number of sampler | 2137133499 | |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | TNT Rebar | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | L159-093-25 | Structure unique identifier | |
| Structure name | Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Welded Hoops | Production or Authorization Testing | Production Testing |
|---|---|---|---|
| Service or Ultimate | Ultimate | Rebar Heat Number(s) | 1201067353 |
| Hoop Manufacturer Lot Number(s) | 1,2 | Material Standard Code | ASTM A706 |
| Material Grade | 60 | Rebar Size | #5 |
| Diameter of Hoop | 3'-2" | Epoxy Coated | No |
| Epoxy Coating Color | NA | Rebar Manufacturer | NUCOR |
| Welding Company | TNT Rebar Company | Coating Standards | Uncoated |
| Weld Type | Flash Welded |
Test Details
DIME Sample ID: 2025-07-07-6
DIME Test ID: 2025-07-07-6-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2025-07-23
Test Results
Number of Samples: 8
Input Type: Measured
Tester's full name: Steven Paine
Date of test: 07/23/2025
UTM: NA
Temperature: 0 f
| Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|
| 1 | 1 | 1 | 5 | 0.31 | 29400 | 95000 | ok necking | Kleinfelder |
| 2 | 2 | 1 | 5 | 0.31 | 29560 | 95500 | ok necking | Kleinfelder |
| 3 | 3 | 1 | 5 | 0.31 | 29510 | 95000 | ok necking | Kleinfelder |
| 4 | 4 | 1 | 5 | 0.31 | 29450 | 95000 | ok necking | Kleinfelder |
| 5 | 1 | 2 | 5 | 0.31 | 29770 | 96000 | ok necking | Kleinfelder |
| 6 | 2 | 2 | 5 | 0.31 | 28710 | 92500 | ok necking | Kleinfelder |
| 7 | 3 | 2 | 5 | 0.31 | 29850 | 96500 | ok necking | Kleinfelder |
| 8 | 4 | 2 | 5 | 0.31 | 28900 | 93000 | ok necking | Kleinfelder |
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 7/23/2025 ✔