Summary for Test 2025-06-16-62-5
Test performed: AASHTO T240-23Project Information
| Project Identifiers | Project ID: 1000282 DEA: 033G0704 EFIS: 0323000121 |
|---|---|
| DIST-CO-RTE-PM | 03-BUT-32-31.5/37.8 |
| Award Date | 06/25/2024 |
| Closeout Date | Not set |
| Work Description | COLD PLANE AND PLACE HMA. |
| Location Description | BUTTE COUNTY FROM 1.6 MILES NORTH OF 120G/PLATT MOUNTAIN ROAD TO TEHAMA COUNTY LINE |
| QA Service Level | 1 (Verified on 05/08/2024) |
Sample Information
| Sample Taken Date | 06/16/2025 | Sample Unique Key | 62 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 06/30/2025 | Sample type | Quality Assurance |
| A brief description of the sample | 1 can | The quantity of what the sample constitutes | 1 |
| From where was the sample collected | Source | First name of sampler or witnessed by | Mark |
| Last name of sampler or witnessed by | Atteberry | Title of sampler | TET |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Teichert Hallwood | |
| Transportation Laboratory (TL) Number | 778840 | Inspector Lot Number from the Transportation Laboratory (TL) Form | |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Asphalt Binder | Performance Grade | PG 58-22 |
|---|---|---|---|
| Modified | No | Lot number | 1 |
| Sublot number | 13 | Tank number | |
| Time of sample | HMA Supplier | Teichert Hallwood | |
| Certified Asphalt Supplier | Pacific Northwest Oil - Stockton CA | Multigrade | No |
| Multigrade Type | Asphalt Binder Mix Number | ||
| HMA Type | Not set | HMA Supplier Mix ID Number | Not set |
Test Details
DIME Sample ID: 2025-06-16-62
DIME Test ID: 2025-06-16-62-5
Testing Lab: Atlas - Denver
Test Method: AASHTO T240-23: Standard Method of Test for Effect of Heat and Air on a Moving Film of Asphalt Binder (Rolling Thin-Film Oven Test)
Test Release Date: 2025-07-23
Test Results
Is mass change based on one or two containers?: Two
Is mass change correction factor needed?: Yes
Input Type: Measured
Tester's full name: Atlas
Date of test: 07/16/2025
Any material loss from containers during heating process/testing?: No
Mass of container #1 before test (m1i): 209.480 grams
Mass of container #2 before test (m2i): 208.844 grams
Mass of container #1 after test (m1f): 209.479 grams
Mass of container #2 after test (m2f): 208.841 grams
Mass of empty container #1: 174.321 grams
Mass of empty container #2: 173.567 grams
Mass correction factor: 0.030
Average mass change: 0.024 percent
General comments (publicly viewable) (Max 1000 characters): MASS CHANGE
Test was verified on 7/23/2025 ✔