Summary for Test 2025-07-12-2-1
Test performed: AASHTO T27-14Project Information
| Project Identifiers | Project ID: 1001312 DEA: 11432844 EFIS: 1125000219 |
|---|---|
| DIST-CO-RTE-PM | 11--- |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Not set |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 07/12/2025 | Sample Unique Key | 2 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/14/2025 |
| Sample type | Production Start-Up | A brief description of the sample | PSU |
| The quantity of what the sample constitutes | 3 bags | From where was the sample collected | Supplier |
| First name of sampler or witnessed by | Gerardo | Last name of sampler or witnessed by | Cordero |
| Title of sampler | TET | Telephone number of sampler | 6199366795 |
| Laboratory sample identification | 25-07-12-2-PSU | Linked DIME Sample ID | 2025-07-12-1 |
| The fabricator/manufacturer/facility name | Vulcan Otay | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | Not Provided |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
| The plant number | A detailed description of where the material sample was collected | Plant | |
| Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 1-1/2 inch | |
| The concrete mix design number | Lot number | ||
| Sublot number | Aggregate Mix Number | 820801 Otay Val |
Combined Gradation Report Information
| Combined Gradation Report Id | Bin Index | Dime Test Id |
|---|---|---|
| 2025-07-26: HMA Aggregates (Size 1-1/2"): Type A HMA - Sieve Analysis With RAP | 1 | 2025-07-12-2-1 |
Test Details
DIME Sample ID: 2025-07-12-2
DIME Test ID: 2025-07-12-2-1
Testing Lab: CT D11 - District 11 Materials Laboratory
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2025-07-24
Test Results
What type of gradation is being tested?: Combined Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Does this test use 1/4 sieve? (question for HMA Gradation Type): No
Has the fine aggregate sample been reduced?: Yes
Input Type: Measured
Tester's full name: Mohammad Abbassi
Date of test: 07/22/2025
| Cumulative Mass Retained | Cumulative Percent Passing | |||||
|---|---|---|---|---|---|---|
| 18419.0 grams | ||||||
| 0.0 grams | 100 % | |||||
| 2786.0 grams | 85 % | |||||
| 5030.0 grams | 73 % | |||||
| 9936.0 grams | 46 % | |||||
| 12098.0 grams | 34 % | |||||
| 14077.0 grams | 24 % | |||||
| 14151.0 grams | 23 % | |||||
| 603.9 grams | ||||||
| 109.6 grams | 19 % | |||||
| 234.7 grams | 14 % | |||||
| 353.4 grams | 10 % | |||||
| 464.1 grams | 5 % | |||||
| 525.0 grams | 3 % | |||||
| 546.9 grams | 2.2 % | |||||
| 548.4 grams | ||||||
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 7/24/2025 ✔